Operator’s Manual

800 Watt Inverter Generator

Check for parts online at

www.getearthquake.com or call 800-345-6007 M-F 8-5

11

AC VOLTAGE

60Hz - 100, 120V, 240V

MAX OUTPUT

800 watts

RATED OUTPUT

700 watts

DC OUTPUT

12V / 3.0A

ENGINE DISPLACEMENT

40cc

ENGINE TYPE

4-cycle

NOISE LEVEL (@7m)

58 dB

FUEL TANK CAPACITY

0.55 gallons (2.1 liters)

FUEL TYPE

Minimum 87 octane gasoline with

NO ethanol content
NOTE: If using an ethanol blended

fuel, a fuel stabilizer, mixed to

manufacturer specifications, is

recommended

RUN TIME (25% load)

8.2 hours

OIL TANK CAPACITY

11.8 ounces (.35 liter)

OIL TYPE

10W-30 (SJ, SL or better)

SPARK PLUG

CMR6A (TORCH)

SPARK PLUG GAP

0.6 - 0.7 mm

WEIGHT OF UNIT

21 lb

UNIT SIZE L x W x H (inches)

15.6 x 8.2 x 14.0

SPECIFICATIONS

OIL WARNING SYSTEM

When the oil level reaches a low level, the engine will stop

automatically. In order to restart the engine, the oil must be

refilled.
NOTE: It is important to check the oil level before each use.

ENGINE SWITCH

The engine switch must be in the ON position to start and run

the generator. Flip the engine switch to the STOP position to

stop the generator. SEE FIGURE 1
NOTE: It is recommended to keep the engine switch in the OFF

position while the generator is not in use.

ECONOMY CONTROL SWITCH

When the economy control switch is in the ON position, the

economy control unit controls the engine speed according to

the connected load. The results are better fuel usage and lower

noise levels. SEE FIGURE 1
NOTE: When starting the generator and while plugging in and

starting connected devices, make sure the economy control switch

is in the OFF position. Flip economy switch to the ON position once

all units are running smoothly.

DC CIRCUIT PROTECTOR

The DC circuit protector turns off automatically when the load

exceeds the generator’s rated output. SEE FIGURE 1
NOTE: If generator turns off due to access load, reduce the load to

within specific generator rated output levels.

FUEL TANK CAP AIR VENT

The fuel tank cap is provided with an air vent knob to stop fuel

flow. The air vent knob must be turned clockwise to the OPEN

position to run the generator. This will allow for fuel flow in

the engine. When the generator is not in use, turn the air vent

knob counterclockwise to the CLOSED position. This will block

air flow to the fuel tank. SEE FIGURE 2

FUEL VALVE

The fuel valve must be in the ON position to run the genera-

tor. When the generator is not in use, turn the fuel valve to the

OFF position. SEE FIGURE 2

FIGURE 1

ENGINE SWITCH

ECON. SWITCH

DC PROTECTOR

ON

OFF

CL

OS

E

O

PE

N

CLOSE

OPEN

ON

OFF

FIGURE 2