Operator’s Manual

800 Watt Inverter Generator

Check for parts online at

www.getearthquake.com or call 800-345-6007 M-F 8-5

14

USING ELECTRICAL POWER

AC Application:
1. Turn off the switch(es) of the electrical device(s) before

connecting to the generator.

2. Insert the plug(s) of the electrical device(s) into the receptacle.
3. Start electrical device(s). Let run for a few moments and then

flip the economy control switch to the ON position.

Overload Indicator Light:
The overload indicator light comes on when an overload of

a connected electrical device is detected, the inverter unit

overheats or the AC output voltage rises. The electronic breaker

will then activate, stopping power to the generator in order to

protect the generator and any connected electric devices. The

output light (green) will flicker and the overload indicator light

(red) will turn on, then the engine will stop running. If so please

follow the following steps:
1. Turn off any connected electric devices.
2. Reduce the total wattage of connected electric devices to be

within the generators range.

3. If total wattage is within range, check for blockages in the

cooling air inlet and around the control unit. If any blockages

are found, remove.

4. Restart engine. Make sure to follow starting instructions.

DC Application (Option):
This usage is applicable to 12V battery charging only. Be sure that

the economy control switch is in the off position while charging

the battery.
1. Connect the battery charging cable to DC receptacle on the

generator.

NOTE: A battery charging cable is included in the box.
2. Connect to the battery terminals using the charging leads.

Make sure the red lead is going to the positive (+) post of the

battery and the black lead is going to the negative (-) post of

the battery.

3. Once the connection is confirmed make sure the DC circuit

protector is in the ON position.

CAUTION

BE SURE THE ELECTRICAL DEVICE(S) IS(ARE) TURNED OFF

BEFORE PLUGGING IN.
BE SURE THAT THE TOTAL LOAD IS WITHIN GENERATOR

RATED OUTPUT.
BE SURE THE SOCKET LOAD CURRENT IS WITHIN THE

SOCKET RATED CURRENT.
THE ECONOMY CONTROL SWITCH MUST BE TURNED TO

THE OFF POSITION WHEN USING ELECTRIC DEVICES THAT

REQUIRE A LARGE STARTING CURRENT.

CAUTION

THE AC OUTPUT OF THE GENERATOR AUTOMATICALLY

RESETS WHEN THE ENGINE IS STOPPED AND THEN

RESTARTED.
THE OVERLOAD INDICATOR LIGHT MAY COME ON FOR A

FEW SECONDS AT FIRST WHEN USING ELECTRIC DEVICES

THAT REQUIRE A LARGE STARTING CURRENT.
BE SURE THE ECONOMY CONTROL SWITCH IS IN THE OFF

POSITION WHILE CHARGING BATTERIES WITH THE DC

APPLICATION.

WARNING

DO NOT USE WORN, BARE, FRAYED OR OTHERWISE

DAMAGED ELECTRICAL CORD SETS WITH THE GENERATOR.

DO NOT HANDLE ANY KIND OF ELECTRICAL DEVICE WHILE

STANDING IN WATER, WHILE BAREFOOT OR WHILE HANDS

OR FEET ARE WET.