RT120 Operator’s Manual

Service - 175

100 Hour

100 Hour

Tractor

Change Engine Oil and Filter (Initial)

Change engine oil and filter at 100 hours if fuel
sulfur content is above 500 ppm (500 mg/kg).
See page 157 for more information about DEO
specifications.

To change:

1.

While oil is warm, remove drain plug (3).
Drain oil and replace plug.

2.

Remove filter (1) and replace with new filter
each time oil is changed. Add DEO at fill
neck (2).

Location

Task

Notes

TRACTOR

Change engine oil (Tier 3)

Initial; if using fuel with sulfur
content above 500 ppm (500
mg/kg)

Lube axle mounts

EPG

Lube driveshaft U-joints

EPG

Lube king pins

EPG

PLOW

Check plow shear mounts

Test plow connector pivots

1

3

2

t41om018w.eps