As Needed

CMW

®

As Needed

Vacuum System

Change Water Pump Filter

1.

Open filter housing.

2.

Remove element and rinse housing
thoroughly with clean water.

3.

Install new element and close filter housing.

Lube Blower for Long-term Storage

Lubricate blower before long-term storage to help
prevent rust and seizing.

1.

Remove filter.

2.

Start engine.

3.

Spray light oil into port and run unit for 1-2
minutes.

4.

Turn off engine.

Location

Task

Notes

VACUUM
SYSTEM

Change water pump filter

Lube blower for longterm storage

Change blower relief air filter

Check battery

DEBRIS
TANK

Clean primary shutoff valve