beautypg.com

Mv800 operator’s manual – Ditch Witch MV800 User Manual

Page 80

background image

MV800 Operator’s

Manual

Service - 79

100 Hour

CMW

®

Change Fuel Filter

Replace filter every 100 hours.

1.

Remove filter.

2.

Install new filter. Apply fuel oil thinly over the
gasket and hand-tighten.

Change Blower Oil

Change oil after the first 100 hours of operation,
and every 1000 hours thereafter. Change oil more
frequently if working in dusty conditions.

Drain at drain plug (4) while oil is warm.

Add SGL at fill (2) until oil is at halfway point
on sight glass (3).