Vacuum and Pothole - 53
Open/Close Tank Door
CMW
®
Hydraulic Door (Optional)
Open
1.
If using optional reverse flow mode, turn off
engine and ensure handle is down (in
“vacuum” mode).
2.
If tank is tilted, lower tank fully before opening
door.
3.
Open tank inlet valve.
4.
Turn handles (1) counterclockwise until door
latches are free. Rotate latches away from
tank.
5.
Set hydraulic function valve to door position.
6.
Push top button on tethered control to open
door.
7.
Ensure door lift latch (1) engages properly.
Door lift latch should be fully seated on pin (2).
Crushing weight could cause death or serious injury. Stay
away.
275-326
To help avoid injury: Do not raise tank with door held closed only by vacuum. Door may suddenly
open and possibly injure someone.
NOTICE: Do not drive with tank or door raised.
IMPORTANT: Depressurize tank before emptying vacuum air filter canister, cleaning filter, clearing
hoses or opening any doors.