Vacuum system, Mv800 operator’s manual – Ditch Witch MV800 User Manual
Page 68
MV800 Operator’s
Manual
Service - 67
10 Hour
CMW
®
Vacuum System
Check Engine Air Filter
Check air filter every 10 hours. Press dust ejector
valve to release dust. Change air filter elements
when air filter restriction indicator (1) reaches the
red zone.
.To change:
1.
Remove air filter cover and remove element.
2.
Wipe inside of housing and wash cover.
3.
Insert new element.
4.
Replace cover.
Check Engine Oil Level
While engine oil is warm, check oil level at dipstick
(2) every 10 hours. Add GEO at fill (1) as necessary
to keep oil level at highest line on dipstick.
NOTICE: Only open the air filter canister when
air restriction is indicated. Change the elements,
do not attempt to clean them.
•
Compressed air or water may damage filter
element.
•
Tapping filter elements to loosen dirt may
damage the element.
- JT5 (161 pages)
- JT922 (159 pages)
- JT9 (165 pages)
- JT20 (195 pages)
- JT1220 (201 pages)
- JT2020 (203 pages)
- JT25 (203 pages)
- JT30 (245 pages)
- JT60 (218 pages)
- JT100 (243 pages)
- AT Air Hammer (11 pages)
- TK Series Manual (61 pages)
- 8500 (77 pages)
- MR90 (121 pages)
- FT5 (28 pages)
- FM5 (57 pages)
- FM13V (46 pages)
- FM25 (67 pages)
- P80 (71 pages)
- OnGrade (63 pages)
- FX20 (100 pages)
- FX25 (119 pages)
- FX30 (149 pages)
- FX50 (141 pages)
- FX60 (157 pages)
- RT Line (115 pages)
- RT30 (97 pages)
- RT45 (203 pages)
- RT55 (177 pages)
- RT100 (161 pages)
- RT115 (252 pages)
- RT120 (223 pages)
- Zahn (105 pages)
- RT80 (203 pages)
- RT115 Q (193 pages)
- RT120 Q (211 pages)
- 100SX (50 pages)
- 410SX (131 pages)
- SK350 (77 pages)
- SK750/SK755 (81 pages)
- SK850 (107 pages)
- SK850 Footings Machine (107 pages)
- 150RT (55 pages)
- 250RT (49 pages)