33


iLM8 - Live may be configured to alert you to an AES lock loss condition.

AES Lock: Allows the AES Lock alarm to be suppressed or enabled. (Default: Off)

About Menu

Model Number: Displays the model number of the unit.

Serial Number: Displays the serial number of this unit.

Build Number: Displays the firmware build number.

Build Date: Displays the firmware build date.

Hardware Rev: Displays the hardware revision level of this unit.

Firmware Rev: Displays the firmware revision level that is running on this unit.

Eclipse Algorithm: Versions of the Eclipse algorithm.

Eclipse Algorithm Rev: Version of the Eclipse algorithm.



Faults


Although your iLM8 - Live will provide you with years of trouble free service, occasionally problems may
occur. Below is a listing of the most common fault conditions.

No Clock: AES sync has been lost. Please check the source equipment and all cable connections.
Ensure that iLM8 - Live is operating in the proper input mode for your application and is looking for the
source audio on the correct port.

CRC Error: iLM8 - Live has encountered a CRC error in the audio stream. Check that equipment up-
stream of iLM8 - Live is properly configured to output the correct audio stream.


Validity Error: iLM8 - Live has encountered a validity error with the audio stream. Check that
equipment up-stream of iLM8 - Live is properly configured to output the correct audio stream.


Bi-phase Error: iLM8 - Live has encountered a bi-phase error with the audio stream. Check that
equipment up-stream of iLM8 - Live is properly configured to output the correct audio stream.

No Parity Error: iLM8 - Live has encountered a parity error with the audio stream. Check that
equipment up-stream of iLM8 - Live is properly configured to output the correct audio stream