C > effects – DaySequerra iLM8 Live User Manual
Page 24
24
iLM8 – Live User Manual
C > Effects
Figure 4d. Dialog vs. Effects Home Screen on iLM8 - Live
C > Effects simultaneously calculates the difference between the full 5.0 mix and 4.0 Bed (L, R, Ls, Rs)
providing the user with a factor in LU that measures how much higher the announcer is (typically +6 to
+10 LU) above the effects for live events. Each field can be customized to the users preference
providing 3 fields of dynamic measurements. By default field# 1 displays the 5.0 Max SL, field# 2 the
Center Channel and field# 3 the calculated value of the Center Channel > the 4.0 Bed
1. Field #1 is defined by the user from a list of measurements that include: Max Short and
Momentary Loudness Avg. combined for 5.0 Surround, 4.0 Bed (Max SL only) and 2.0 Stereo,
Infinite Avg. for Surround and Stereo, Measured value of C > 4.0 Bed, Short loudness Avg. of
an individual Surround Channel (L, R, C, Ls, Rs), True Peak for Surround and Stereo, Max – TP
for Surround and Stereo, LRA for Surround and Stereo.
2. Field #2 is defined by the user from a list of measurements that include: Max Short and
Momentary Loudness Avg. combined for 5.0 Surround, 4.0 Bed (Max SL only) and 2.0 Stereo,
Infinite Avg. for Surround and Stereo, Measured value of C > 4.0 Bed, Short loudness Avg. of
an individual Surround Channel (L, R, C, Ls, Rs), True Peak for Surround and Stereo, Max – TP
for Surround and Stereo, LRA for Surround and Stereo.
3. Field #3 is defined by the user from a list of measurements that include: Max Short and
Momentary Loudness Avg. combined for 5.0 Surround, 4.0 Bed (Max SL only) and 2.0 Stereo,
Infinite Avg. for Surround and Stereo, Measured value of C > 4.0 Bed, Short loudness Avg. of
an individual Surround Channel (L, R, C, Ls, Rs), True Peak for Surround and Stereo, Max – TP
for Surround and Stereo, LRA for Surround and Stereo.
4. Indicates the current measurement that is displayed in Field #1.
5. Indicates the current measurement that is displayed in Field #2
6. Indicates the current measurement that is displayed in Field #3
7. Play / Stop / Reset Infinite Average icon. Selecting this icon while on the Home Screen and
pressing ENTER will ‘stop’ the Infinite Average. Pressing ENTER once again will ‘reset’ the