Page 5

background image

ZDW232 Instructions, Release 1.1

P/D 100407

HomePro

by ADVANCED CONTROL TECHNOLOGIES, INC.

0747-01

5

There are 3 sets of parameters that can adjust the dimming rate of the ZDW232.

1. One set to control how fast the dim rate is when the dimmer receives a Z-Wave command

excluding ALL ON or ALL OFF command (Parameter 7 and 8).

2. One set to control how fast the dim rate is when the dimmer is locally controlled (Parameter 9 and 10).
3. One set to control how fast the dim rate is when the dimmer receives an ALL ON or ALL OFF command

(Parameter 11 and 12).

These values can be changed instantly to allow various scenes and effects.
The first of these parameters is the “dim step” (dim rate) parameter. It can be set to a value of 1 to 99. This value
indicates how many levels the dimmer will change when the timer (discussed below) expires.
The second parameter is the timing (how fast the dim rate) parameter. It can be set to a value of 1 to 255.
This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this
parameter to 1, then every 10mS the dim level will change. If you set it to 255, then every 2.55 seconds the dim level
will change.
With the combination of the two parameters that can control the dim rate, the dimmer can be adjusted to dim from
max to min or min to max at various speeds between 10 millisecond and 252.45 seconds (over 4 minutes).

On/Off Command dim rate (excluding ALL ON/ALL OFF commands)

Parameter 7

Dim step Parameter (default value is 1)
Valid Values: 1-99

Parameter 8

Dim timer Parameter (default value is 3)
Valid Values: 1-255
Local Control dim rate

Parameter 9

Dim step Parameter (default value is 1)
Valid Values: 1-99

Parameter 10 Dim timer Parameter (default value is 3)

Valid Values: 1-255
ALL ON/ALL OFF dim rate

Parameter 11 Dim step Parameter (default value is 1)

Valid Values: 1-99

Parameter 12 Dim timer Parameter (default value is 3)

Valid Values: 1-255

Enable Shade Control Group 2

• Parameter 14
• Length: 1 Byte
• Valid Values: 0 or 1 (default value is 0)

The ZDW232 can operate shade control devices via its group 2 if this configuration parameter is set to 1.

Enable Shade Control Group 3

• Parameter 15
• Length: 1 Byte
• Valid Values: 0 or 1 (default value is 0)

The ZDW232 can operate shade control devices via its group 3 if this configuration parameter is set to 1.

LED Transmission Indication

Parameter 19

Length: 1 Byte

Valid Values = 0 , 1, 2 (default value is 2)