Advanced Control Technologies Specs Instructions ZDW232 (RF 230 VAC, 500W, IncandescentWall Dimmer,Two Wire, White) User Manual
Page 4

ZDW232 Instructions, Release 1.1
P/D 100407
HomePro
by ADVANCED CONTROL TECHNOLOGIES, INC.
0747-01
4
Suspend Group 4
• Parameter No: 2
• Length: 1 Byte
• Valid Values = 0 or 1 (default value is 0)
You may wish to disable transmitting commands to Z-Wave devices that are in Group 4 without “un-associating”
those devices from the group. Setting parameter 2 to the value of 1 will stop the ZDW232 from transmitting to devices
that are “associated” into Group 4.
It is possible that you may only want the units in Group 4 to track when the dimmer is being turned ON and OFF
and not when dimming.
Disable Group 4 During a Dim Command
•
Parameter 13
•
Length: 1 Byte
•
Valid Values = 0 or 1 (default value is 0)
After the ZDW232 is commanded to stop dimming, it will then command the Z-Wave devices in Group 4 to the
ZDW232’s new level. To prevent the ZDW232 from commanding the Z-Wave devices in Group 4 during this particular
occurrence, set Parameter 13 to the value of 1.
Night Light
• Parameter No: 3
• Length: 1 Byte
• Valid Values = 0 or 1 (default value is 0)
The LED on the ZDW232 will by default, turn ON when the load attached is turned ON. To make the LED turn ON
when the load attached is turned OFF instead, set parameter 3 to a value of 1.
Invert Switch
• Parameter No: 4
• Length: 1 Byte
• Valid Values = 0 or 1 (default value is 0)
To change the top of the switch to OFF and the bottom of the switch to ON, set parameter 4 to 1.
Ignore Start Level When Receiving Dim Commands
• Parameter No: 5
• Length: 1 Byte
• Valid Values = 0 or 1 (default value is 1)
The ZDW232 can be set to ignore the start level that is part of the dim command, regardless of whether the command
is telling the dimmer to ignore the start level or not ignore the start level embedded in the command (see Parameter
1). Setting parameter 5 to a value of 1 (factory default) will cause the ZDW232 to ignore the start level and to dim
or brighten from its current level. Setting the value to 0 will cause the ZDW232 to dim or brighten from the level in
the command.
Don’t Send Level Command After Transmitting Dim Commands
• Parameter 6
• Length: 1 Byte
• Valid Values = 0 or 1 (default value is 1)
When you press and hold the bottom of the ZDW232 switch once, the Z-Wave devices that are associated into Group
1 are sent the Dim command. If parameter 6 is set to 0, after you release the switch, the ZDW232 will command
devices in that group to go to the same level of the ZDW232. If parameter 6 is set to a value of 1 (factory default)
the devices in Group 1 will not go to the same level of the ZDW232
Adjusting Dim Rate
• Parameter 7-12
• Length: 1 Byte
• Valid Values: (See next)