Gigabit ethernet – ADLINK Express-IB User Manual
Page 18

Page 18
Express-IB
Signal
Pin #
Description
I/O
PU/PD
Comment
LVDS_B1+ 
LVDS_B1- 
LVDS_B2+ 
LVDS_B2- 
LVDS_B3+ 
LVDS_B3- 
B73 
B74 
B75 
B76 
B77 
B78 
LVDS_B_CK+ 
LVDS_B_CK- 
B81 
B82 
LVDS Channel B differential clock
O LVDS
LVDS_VDD_EN
A77
LVDS panel power enable
O 3.3V
LVDS_BKLT_EN
B79
LVDS panel backlight enable
O 3.3V
LVDS_BKLT_CTRL
B83
LVDS panel backlight brightness control
O 3.3V
LVDS_I2C_CK
A83
DDC lines used for flat panel detection and control.
O 3.3V
PU 2k2 3.3V
LVDS_I2C_DAT
A84
DDC lines used for flat panel detection and control.
I/O 3.3V
PU 2k2 3.3V
3.3.4. Gigabit Ethernet
Gigabit Ethernet
Pin #
Description
I/O
PU/PD
Comment
GBE0_MDI0+ 
GBE0_MDI0- 
GBE0_MDI1+ 
GBE0_MDI1- 
GBE0_MDI2+ 
GBE0_MDI2- 
GBE0_MDI3+ 
GBE0_MDI3- 
A13 
A12 
A10 
A9 
A7 
A6 
A3 
A2 
Gigabit Ethernet Controller 0: Media Dependent Interface Differential 
Pairs 0, 1, 2, 3. The MDI can operate in 1000, 100, and 10Mbit/sec 
modes. Some pairs are unused in some modes according to the 
following: 
1000BASE-T
100BASE-TX
10BASE-T
MDI[0]+/- B1_DA+/-
TX+/- TX+/-
MDI[1]+/- B1_DB+/-
RX+/- RX+/-
MDI[2]+/- B1_DC+/- 
MDI[3]+/- B1_DD+/- 
I/O Analog
Twisted pair 
signals for 
external 
transformer. 
GBE0_ACT#
B2
Gigabit Ethernet Controller 0 activity indicator, active low.
O 3.3VSB
GBE0_LINK#
A8
Gigabit Ethernet Controller 0 link indicator, active low.
O 3.3VSB
GBE0_LINK100#
A4
Gigabit Ethernet Controller 0 100Mbit/sec link indicator, active low.
O 3.3VSB
GBE0_LINK1000#
A5
Gigabit Ethernet Controller 0 1000Mbit/sec link indicator, active low.
O 3.3VSB
GBE0_CTREF
A14
Reference voltage for Carrier Board Ethernet channel 1 and 2 
magnetics center tap. The reference voltage is determined by the 
requirements of the Module PHY and may be as low as 0V and as high 
as 3.3V. The reference voltage output shall be current limited on the 
Module. In the case in which the reference is shorted to ground, the 
current shall be 250 mA or less. 
GND min 
3.3V max 