@Description
Set digital output channel value at specified address. This command is
only available to modules involving the multiport digital output function.
@Syntax
#(Addr)T(OutDataH)(OutDataL)
#(Addr)T(OutDataA)(OutDataB)(OutDataC) (6058 only)
#
Command leading code. (1-character)
(Addr)
Address ID (2-character)
T
Set value to all channels
(OutDataH)
Each bit is mapping to each channel number from 14
to 8. (2-character)
(OutDataL)
Each bit is mapping to each channel number from 7
to 0. (2-character)
(OutDataA)
Output data for port A. Each bit is mapping to each
channel number from 7 to 0. (2-character)
(OutDataB)
Output data for port B. Each bit is mapping to each
channel number from 7 to 0. (2-character)
(OutDataC)
Output data for port C. Each bit is mapping to each
channel number from 7 to 0. (2-character)
* if the port of ND-6058 is in input mode, output data to this port will be
ignore.
@Response
or
?(Addr)
>
Command is valid
?
Command is invalid.
(Addr)
Address ID.