Overview of NuDAM -6054

1.5.1

What is NuDAM-6054 ?

NuDAM-6054 provides 15 isolated digital input channels. All of the input
channels are common power type and one of them is using the same pin
with default (use jumper to choose). The isolation voltage is up to 5000
Vrms. It is suitable to use NuDAM-6054 in industrial environment with the
dangerous of high voltage electric shock.

1.5.2

Features of NuDAM-6054

15 bits digital inputs with isolation protection and common power

5000 Vrms isolation voltage

Programmable host watchdog timer for host failure protection

Internal watchdog timer for device failure protection

Easy programming by software

Easy installation and wiring

1.5.3

Specifications of NuDAM-6054

Interface

Interface : RS-485, 2 wires

Speed (bps) : 1200, 2400, 4800, 9600, 19.2K, 38.4K, 115.2K
(115.2K only for firmware reversion above A4.00)

Input

Channel numbers : 15 isolation common power input channels
(the fifteenth channel is the same with default pin, but can use
jum per to choose)

Input type : source type

Effective distance: 500 m

Common external voltage: 24V

Watchdog Function