Return code – ADLINK PCI-7300A User Manual
Page 75

C/C++ Libraries
63
PAON_PBOFF: PORTA terminator ON, PORTB terminator
OFF
PAON_PBON: PORTA terminator ON, PORTB terminator
ON
Note:
term_cntrl is used to control the ON/OFF of the active termi-
nators, not terminal power output: TERMPER)
cntrl_pol:The polarity configuration. This argument is an inte-
ger expression formed from one or more of the manifest constants
defined in 7300.h. There are six groups of constants:
@ Return Code
NoError
PCICardNumErr
PCICardNotInitInvalidDIOConfigure
(1) DIREQ
DIREQ_POS:
DIREQ signal is rising edge active
DIREQ_NEG:
DIREQ signal is falling edge active
(2) DIACK
DIACK_POS:
DIACK signal is rising edge active
DIACK_NEG:
DIACK signal is falling edge active
(3) DITRIG
DITRIG_POS:
DITRIG signal is rising edge active
DITRIG_NEG: DITRIG signal is falling edge active
(4) DOREQ
DOREQ_POS: DOREQ signal is rising edge active
DOREQ_NEG: DOREQ signal is falling edge active
(5) DOACK
DOACK_POS: DOACK signal is rising edge active
DOACK_NEG: DOACK signal is falling edge active
(6) DOTRIG
DOTRIG_POS: DOTRIG signal is rising edge active
DOTRIG_NEG: DOTRIG signal is falling edge active