B.

1

4

4

2

3

18T Series Installation

2

Cartridge Installation

A.

Turn off water supplies. Remove
cover (1), bonnet nut (2) and test cap (3)
from the body. If this is not a thin wall

mounting, the entire plasterguard (4)

may be removed. If screen (5) is in place,

remove before installing cartridge.

1

2

3

17

C.

Slide bonnet nut (1) over the cartridge

and thread onto the body. Hand tighten

securely.

1

4

Rotate the cartridge (1) so the word

“UP” (2) appears on the top. Insert

cartridge into valve body as shown. Make

sure the cartridge tubes and O-rings (3)

are properly seated in holes at the base of

the body. Ensure the keys on the body are

fully engaged with the slots in the body (4).

For back to back or reverse installations (hot

on right and cold on left): Rotate cartridge (1)

so the word “UP” (2) appears on the bottom.

Install the cartridge making sure that the

keys are fully engaged with the slot in the

brass body (see step B). Slide bonnet nut (3)

over the cartridge and thread onto the body.

Hand tighten securely.

Back to back Installation

Normal Installation

(changes not required)

Reverse

Installation

Cold

Hot

1

3

2