Existing Fireplace

Installation

Seal all drafts and vents

1.

with non-fibrous insulation

materials to prevent chimney

debris from falling into the

fireplace insert. Do not install

into an existing fireplace

that is prone to leaks or

dampness.
Cap the top of the chimney

2.

flue to prevent rain from

entering.

Plan your electrical power

3.

supply (refer to noTE 1).
The power cord can run along

4.

the front of the hearth to an

outlet near the fireplace.

WARNINg: To prevent

personal injury you should

hire a professional to cap the

chimney flue or cut a hole

in the existing fireplace for

wiring. If you return your

existing fireplace to its original

use (example: wood burning),

it should be inspected by the

local building department prior

to use to reduce the risk of fire

and personal injury.

New Wall Construction

select a suitable location that

1.

is not susceptible to moisture

and is away from drapes,

furniture and high traffic.
Place the fireplace in the

2.

desired location to see how it

will look in the room.
mark the desired location

3.

on the floor and store the

fireplace in a safe, dry and

dust free location.
Use studs to frame an

4.

opening of 30 ¾ inch (78.1

cm) wide X 25 ¾ inch (65.4

Site Selection and Preparation

Figure 1

Air Circulation Areas

Rubber

Feet

25 ½”

(64.8 cm)

30 ¼”

(76.8 cm)

11 ½”

(29.2 cm)