3

33

3

2

2--1

1 SSIIR

REEN

N O

OU

UTTP

PU

UTT CCO

ON

NSSTTA

AN

NTT//P

PU

ULLSSEED

D:: The system can be programmed to output pulses instead of a continuous

output when the system is triggered. This is useful to honk the factory horn in applications where a siren is

undesirable. Remember that the unit is only capable of supplying 1 amp of current. A relay will be required to

interface with most factory horn systems.

2

2--2

2 SSIIR

REEN

N D

DU

UR

RA

ATTIIO

ON

N 3

30

0//6

60

0 SSEECCO

ON

ND

DSS:: It is possible to program the unit to sound for 30 or 60 seconds

during the triggered sequence. Some states have laws regulating how long a security system can sound.

When using the ProSecurity Programmer, the siren can be programmed to sound for any length of time from 1

second to 180 seconds. Use the right and left arrows or the plus (+) and minus (-) keys on the keyboard to

change the siren duration in 1 second intervals. Holding down the key will rapidly increase or decrease the setting.

2

2--3

3 N

NU

UIISSA

AN

NCCEE P

PR

REEV

VEEN

NTTIIO

ON

N CCIIR

RCCU

UIITTR

RY

Y™

™ ((N

NP

PCC™

™)) O

ON

N//O

OFFFF:: NPC™ stops repeated triggering of the same zone. If

one zone is triggered three times in one hour, that zone is bypassed for one hour, starting from the time of the

third trigger. During that hour, if the system sees a trigger on that zone again, the system resets the one hour

timer. If one hour passes and the zone has not triggered again, the zone is activated and can trigger the system

again. NPC™ only monitors sensor inputs, and does not bypass the door trigger or the ignition trigger at any

time. If NPC™ is turned off, the system will respond to repeated triggers on the sensor inputs and will do so

indefinitely. Some states have laws regulating how many times a security system can trigger before it is con-

sidered a nuisance and the vehicle is towed away.

2

2--4

4 P

PR

RO

OG

GR

REESSSSIIV

VEE D

DO

OO

OR

R TTR

RIIG

GG

GEER

R O

ON

N//O

OFFFF:: The system responds to a door trigger input with a progressive

response. When the door is opened with the system armed, the siren will chirp 10 times prior to the full trig-

gered sequence. The door trigger is still treated as an instant trigger and closing the door quickly will not

prevent full triggered sequence from occurring. If the progressive door trigger is programmed off, the full siren

output will occur the moment the door is opened.

2

2--5

5 V

VA

ALLEETT P

PU

ULLSSEE CCO

OU

UN

NTT 1

1 TTO

O 5

5 P

PU

ULLSSEESS:: The system can be programmed to count the number of presses of the

valet switch before disarming the security system. The factory default setting is one pulse. The unit can also be

set for two to five pulses.

Ghost Switch option: For added security, the GRAY wire on the two-pin Valet®/Program plug can be connected

to any switch in the vehicle that provides a negative (-) momentary pulse.

2

2--6

6 D

DO

OO

OR

R SSEEN

NSSO

OR

R B

BY

YP

PA

ASSSS CCH

HIIR

RP

P O

ON

N//O

OFFFF:: This feature controls the error chirp that is generated if the system

is armed with the door trigger active. This is useful in vehicles that have a long dome light delay after the door

has been closed. If the system is armed before the dome light has turned off, the security system will generate

the door trigger error chirp. If this error chirp is not desired, use this feature to disable the door open error

chirp. If the bypass chirp is turned off, no bypass chirp will be generated, even if a door is accidentally left

open.

m