Collegamento elettrico, Electrical connection, Warning: this appliance must be earthed – ZANKER GS 105 User Manual
Page 16: Important
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Green and Yellow
to Earth
13 amp
Fuse
Blue to
Neutral
Brown
to Live
Cord
Clamp
O
COLLEGAMENTO ELETTRICO
Controllare che la tensione dell'impianto elettrico corrisponda a quella indicata sullo
targhetta caratteristiche posta sul loto sinistro in basso nella parte interna dello scom
parto congelatore.
Se la presa a muro è priva di contatto a terra, o se la spina non è adatta al vostro
impianto vi consigliamo di rivolgervi od un elettricista speciolizzato.
Non impiegare adattatori o derivatori che potrebbero causare riscaldamenti e bru
ciature.
ELECTRICAL CONNECTION
Check that the main voltage corresponds to that indicated on the rating plate in the
lower left side inside the freezer compartment.
If the wall socket does not have on earth terminal, or if the plug does not fit info the
socket, it is advisable to consult a qualified electrician. Do not use multiple plugs or
adapters as they could cause heating and burning.
WARNING: THIS APPLIANCE MUST BE EARTHED
If this appliance is fitted with a non rewirable plug for which your socket is unsuitable,
the plug should be cut off and an appropriate plug fitted. The removed plug must be
disposed of Insertion of the plug into o 13 Amp socket is likely to cause an electrical
hazord When a nonrewirable plug ora rewirable 13 Amp (BS1363) plug is used it
must befitted with a 13 Amp ASIA approved (BSl 362) fuse. If any other type of plug
16
is used it must be protected by a 15 Amp fuse either in the plug or at the distribution
board
IMPORTANT:
THE WIRES IN THE MAIN LEADS ARE COLOURED IN ACCORDANCE WITH
THE FOLLOWING CODE;
GREEN AND YELLOW • EARTH BLUE - NEUTRAL
BROWN - LIVE
As the colours of the wires in the main lead of your appliance may not correspond
with the coloured marking identifying the terminals in your plug, proceed as follows.
CONNECT GREEN & YELLOW coloured wire to plug terminal marked letter "E" or
earth symbol -4^ or coloured green or green & yellow,
CONNECT BLUE coloured wire to plug terminal marked letter "N" or coloured black.
CONNECT BROWN coloured wire to plug terminal marked letter "L" or coloured
red.