TB-SE
TB-10M single-master system with a door station
• The # terminals on the master station connect to
terminal 1 on each TB-SE sub. These numbers
become the sub's station number, numbered from
the top on each 10-button row.
* 2 parallel wires per TB-SE sub, nonpolarized.
Be sure to run each pair of wires directiy to
TB-M master.
E iine in each pair shouid not be connected at
any other point of cabie than E terminais on
TB-M, which can accomodate 2 ~ 3 TB-SE subs.
Master station
TB-10M
Door adaptor
TB-AD1
IF-DA
-1
- 2
Eh
12V
IN
AC15-16V
or DC18V
-10
12V OUT
12V
T
R
S
S
-►To: power supply
-►
Sub station
TB-SE
Any # terminal on TB-M or TB-G
add-on selector.
★ Do not connect any power source here.
Call extension
IER-2
(one per TB-M)
f
"
f
~|
>
The master can select the door station for audio monitoring at any time. The call
announce pretone is selectable.
Set the switch to ON position for pretone, removing the cover of front case.
■ Wiring distance
TB-M to TB-SE sub
Diameter
0.65mm
0.8mm
1.0mm
Distance
400m
600m
900m
AWG
22AWG
20AWG
18AWG
Distance
1,300'
2,000'
3,000'
TB-AD1 to audio door station
Diameter
0.65mm
0.8mm
1.0mm
Distance
150m
230m
360m
AWG
22AWG
20AWG
18AWG
Distance
500'
750'
1,200'
TB-M to TB-AD1
Diameter
0.65mm
0.8mm
1.0mm
Distance
65m
100m
150m
AWG
22AWG
20AWG
Distance
210'
330'
18AWG
495'
TB-AD1
can be muted by switching
to OFF.
• 5 -