Pantilt myh-cu 3-camera system with lef-10, Mounting, Wiring – Aiphone MYW-BA User Manual
Page 3: My-1cd long-distance application, My-2cd 2 pantilt door long-distance application
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

PanTilt MYH-CU 3-camera system with LEF-10
MYW-P3L adaptor provides LEF-10 with PanTilt door communication capabilities, including visual
checking of 3 entries, and selected entry listening with its image.
The above example illustrates 2 PanTilt door stations and an overhead viewing camera MY-CA
(in MYW-CA) are connected to 7-call LEF-10 system.
MOUNTING
Loosen a front bottom screw and open the front case, sliding front case upward from the chassis.
Unplug the connector from the chassis, and set aside the front main unit.
The chassis mounts to wall with 83.5mm, 3-5/16” pitched.
Make wire terminations on 4 screw terminals, then DC18V wires from power supply.
Reconnect and attach the front case to chassis, and tighten the bottom screw.
WIRING
MY-1CD long-distance application
MY-1CD is basic 1 door -1 monitor PanTilt system. With an MYW-BA added, MY-1CD now communicates with
PanTilt door station at gate, which is 300m(980’) away.
PanTilt door station
MY*DC/A
300m / 1.2mm dia.
980716AWG
PS-18D(18C)i
MY-2CD 2 PanTilt door long-distance application
MY-2CD matches for the system with 2 PanTilt doors. One MYH-2CD sub monitor(max. 2) may be added,
featuring same operations as on main monitor, and audio/video monitoring independently operable.
I Total of 6 conductors
(• w/2 each wires on
I
1
,- terminals