Direct spark ignition (dsi), Module, Caution – American Dryer Corp. 30 lb. Stacked Models User Manual
Page 26
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
6. Try to restart the dryer with the main door open.
7. The microprocessor (computer) board's L.E.D. display
must read "DOOR".
8. Close the main door and restart the dryer.
9. Functional check of the microprocessor (computer) board is complete.
DIRECT SPARK IGNITION (DSI)
MODULE
Indicator
ж PJtlisM?*
о
- P
ohit
EB>obll*htd|
tf rtd fridcafor '• 'Or* солНпооиЫу.
dfcontnue power for 30 tecood«
*4 ond >hen reetioblieh power If red
indico>or etilt retnaiPt *0n'
conllnuoueiy. replace control
lyjiion sequtncel
- Floiite Conhrftie^
»4
• ignitor> Polled I
CaniQi locfctd QuH
Direct 8park
Ignition Control
S T A T U S
FOR USE VfiTH ALL GASES
ГЧмЛ: 24 VAC 50/60И2 .1 Ara
coniocte: 1 Aflp Conllmeue
Prepurge 15 Secondf Mo*.
Trial For Ignition: 5 Stconde Ho«
Lockout 6 Seconde Hpx
WARNINQ I
Disconnect Power Before Servicing
NOT FIELD REPAIRABLE. Explosion and
Serious Injury May Result
□ □ □ □
1. Upon completing installation of
the replacement Direct Spark
Ignition (DSI) module,
reestablish power to the dryer.
2. Start the drying cycle.
3. The Ignition (DSI) module's
L.E.D. indicator will light "red" for
up to approximately 1.5 seconds
(prepurge time).
4. The module's indicator light will
then turn "green". The gas valve
will be energized and the ignitor probe
will spark for approximately 8
seconds. The burner flame should
now be established.
5. With the burner flame on, remove
the flame sensor wire from the
FS terminal of the DSI module.
6. The burner flame
must shut off
and the ignition module
must
lock out with the DSI module's
indicator light "red".
7. Stop the drying cycle, with the
flame sensor wire still removed,
restart the drying cycle.
8. The ignition module
must proceed through the prepurge, with the indicator light
"red", the ignition trial time of approximately 8 seconds, with the indicator light
"green", and then proceed to lock out with the indicator light "red".
9. Functional check of the Direct Spark Ignition (DSI) Module is complete.
Replace the flame sensor wire from the FS terminal to the DSI module.
CAUTION
LABEL ALL WIRES PRIOR TO DISCONNECT WHEN SERVICING THE
COMPUTER BOARD AND THE IGNITION MODULE. WIRING ERRORS CAN
CAUSE IMPROPER AND DANGEROUS OPERATION.
24