SINGLE DRYER VENTING

INSPECTION

DOOR

HORIZONTAL

MULTIPLE DRYER VENTING

WIDTH 8" DIAMETER EXHAUST

NO. OF DRYERS

4

3

2

1

Minimum cross
section area (sq. in.)

240

180

120

60

Minimum round

duct diameter (in.)

16

14

12

8

NOTEA

HORIZONTAL

NOTEA

VERTICAL

INSPECTION
DOORS

ROOF

1.625" MIN.

TO INDIVIDUAL DRYERS

T"---------------- -- / I

UMbLtR EXHAUST MUST ENTER MAIN

^

29.f

T

WALL EXHAUST DUCT AT A 45» ANGLE.

2 X D CLEARANCE

NOTE: FOR THE INTRODUCTION OF EACH 8" DUCT FROM

'''HE DRYERS, ADD

60 so.

IN. TO THE CROSS

SECTIONS OF THE MAIN DUCT.

FORMULAS TO CALCULATE DUCTING CROSS SECTIONAL AREA

CROSS SECTIONAL AREA OF ROUND DUCT = .785 x WHERE D = DIAMETER OF THE DUCT.

CROSS SECTIONAL AREA OF RECTANGULAR DUCT = W x H WHERE W = WIDTH AND H = HEIGHT.

1

H

-H w 1^

NOTE A: OPENING MUST BE TWO (2) INCHES LARGER THAN DUCT (ALL THE WAY AROUND). THE DUCT

MUST BE CENTERED WITHIN THIS OPENING.

11