American Dryer Corp. 30 lb. Stacked Models User Manual
Page 24
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

6 Months
Remove lint accumulation from around the openings in the dryers back
panels.
Remove lint from gas valve burner train area with a dusting brush or
vacuum cleaner attachment.
Remove any lint accumulation from inside control box and at rear area
behind control box.
Remove any lint accumulation from coin acceptor area, including coin
optic switch.
Inspect and remove lint accumulation in customer furnished exhaust duct
work system and from dryers internal exhaust ducting.
WARNING: THE ACCUMULATION OF LINT IN THE EXHAUST DUCT WORK
CAN CREATE A POTENTIAL FIRE HAZARD.
WARNING: DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND
VENTILATION AIR.
Inspect and remove lint accumulation from the dryer exhaust duct work
back draft dampers.
NOTE:
A back draft damper that is sticking partially closed can result in
slow drying and shutdown of the heat circuit safety switches or
thermostats.
In the cleaning of the cabinet, avoid using harsh abrasives. A product
intended for the cleaning of appliances is recommended.
ADJUSTMENTS
Suggested
Interval
Function
7 Days
Inspect bolts, nuts screws (bearing set screws), non-permanent gas
After
connections (unions, shut-off valves, orifices, etc.), electrical
Installation terminations, and grounding connections. AND....
Every 6
Motor and drive belts should be examined. Cracked or seriously frayed
Months
belts should be replaced. Tighten loose V-Belts when necessary and
check belt alignment.
Complete operational check of controls and valves.
Complete operational check of all safety devices (door switches, lint
compartment switched, sail switch, burner and hi-limit thermostats.)
LUBRICATION
The motor bearings, idler bearings, and tumbler bearings are permanently lubricated and
no relubrication is necessary.
22