The elryer and its individual shut-off valve

must be disconnected from the gas supply
piping system during any pressure testing
of that system at test pressures in excess
of 1/2 psig (3.5 kPa).

The dryer must be isolated from the gas
supply

piping

system

by

closing

its

individual manual shut-off valves during

any pressure testing of the gas supply
piping system at test pressures equal to
or less than 1/2 psig (3.5 kPa).

IMPORTANT:

Failure to

isolate or

disconnect dryer from supply as noted can
cause irreparable damage to the gas
valves ... voiding the warranty.

WARNING: FIRE OR EXPLOSION COULD
RESULT.

Gas Supply

The gas dryer installation must meet the

American

National

Standard,

National

Fuel

Gas

Code

ANSI

Z223.1

(Latest

Edition), as well as local codes and
ordinances and must be done by a
qualified professional.

NOTE:

undersized gas piping will result in

ignition

problems,

slow

drying,

and

increased use of energy and can create a

safety hazard.

The dryer must be connected to the type

of heat/gas indicated on the dryer data
label located on the inside of the middle
access (control) door. If this information
does not agree with the type of gas
available, contact the distributor who sold
the dryer or the factory.

IMPORTANT:

Any

burner

changes

or

conversions must be made by a qualified

professional.

The input ratings shown on the dryer data

label are for elevations of up to 2,000 feet
unless

elevation

requirements

of

over

2,000 feet were specified at the time the
dryer order was placed with the factory.

The adjustment for dryers in the field for

elevations over 2,000 feet are made by
changing each burner orifice. If this
adjustment

is

necessary,

contact

the

distributor who sold the dryer or contact
the factory.

Technical Gas Data

Gas Specifications

Type of Gas

Natural

Liquid Propane (L.P.)

Manifold Pressure*........................................... 4.0 Inches W.C.

10.5

Inches W.C.

In-Line Pressure (W.C.).................................... 6.0 In. to 12.0 In.

10.5 Inches W.C.

Orifice Size (D.M.S.)......................................... #20

#38

Gas Inlet Size............................................................. 3/4" N.P.T.

BTUH Input (each tumbler)........................................ 72,000
BTUH Input (per dryer)............................................. 144,000

* Measured at gas valve pressure tap when the gas valve is on. Measured in inches of water

column.

(D.M.S.) Drill Manufacturer's Standard - equivalent to standard twist drill or steel wire
gauge numbers.

(W.C.) Water column in inches.