Gas supply, Technical gas data, Type of gas – American Dryer Corp. 30 lb. Stacked Models User Manual
Page 16
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
The elryer and its individual shut-off valve
must be disconnected from the gas supply
piping system during any pressure testing
of that system at test pressures in excess
of 1/2 psig (3.5 kPa).
The dryer must be isolated from the gas
supply
piping
system
by
closing
its
individual manual shut-off valves during
any pressure testing of the gas supply
piping system at test pressures equal to
or less than 1/2 psig (3.5 kPa).
IMPORTANT:
Failure to
isolate or
disconnect dryer from supply as noted can
cause irreparable damage to the gas
valves ... voiding the warranty.
WARNING: FIRE OR EXPLOSION COULD
RESULT.
Gas Supply
The gas dryer installation must meet the
American
National
Standard,
National
Fuel
Gas
Code
ANSI
Z223.1
(Latest
Edition), as well as local codes and
ordinances and must be done by a
qualified professional.
NOTE:
undersized gas piping will result in
ignition
problems,
slow
drying,
and
increased use of energy and can create a
safety hazard.
The dryer must be connected to the type
of heat/gas indicated on the dryer data
label located on the inside of the middle
access (control) door. If this information
does not agree with the type of gas
available, contact the distributor who sold
the dryer or the factory.
IMPORTANT:
Any
burner
changes
or
conversions must be made by a qualified
professional.
The input ratings shown on the dryer data
label are for elevations of up to 2,000 feet
unless
elevation
requirements
of
over
2,000 feet were specified at the time the
dryer order was placed with the factory.
The adjustment for dryers in the field for
elevations over 2,000 feet are made by
changing each burner orifice. If this
adjustment
is
necessary,
contact
the
distributor who sold the dryer or contact
the factory.
Technical Gas Data
Gas Specifications
Type of Gas
Natural
Liquid Propane (L.P.)
Manifold Pressure*........................................... 4.0 Inches W.C.
10.5
Inches W.C.
In-Line Pressure (W.C.).................................... 6.0 In. to 12.0 In.
10.5 Inches W.C.
Orifice Size (D.M.S.)......................................... #20
#38
Gas Inlet Size............................................................. 3/4" N.P.T.
BTUH Input (each tumbler)........................................ 72,000
BTUH Input (per dryer)............................................. 144,000
* Measured at gas valve pressure tap when the gas valve is on. Measured in inches of water
column.
(D.M.S.) Drill Manufacturer's Standard - equivalent to standard twist drill or steel wire
gauge numbers.
(W.C.) Water column in inches.
14