IMPORTANT INFORMATION ABOUT THIS WATER HEATER

This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor

ignition incident. The new technology used in meeting these standards makes this product more sensitive to installation
errors. Please review the following checklist and make any required installation upgrades or changes.

Questions? Contact Residential Technical Assistance by referencing the phone number on the water heater.

Installation Checklist

Water Heater Location

Water heater location is important and can affect system

performance. Please check the following:

Installation area free of corrosive elements and

flammable materials.

Centrally located with the water piping system (For new
installations). Located as close to the gas piping and
vent pipe system as possible.

Located indoors and in a vertical position. Protected

from freezing temperatures.

Proper clearances from combustible surfaces
maintained and not installed directly on a carpeted floor.

Provisions made to protect the area from water damage.
Metal drain pan installed and piped to an adequate
drain.

Sufficient room to service the water heater. See
Clearances and Accessibility section of this manual.

Water heater not located near an air moving device.

Is the installed environment dirty (excessive amounts

of lint, dirt, dust, etc.)? If so, the base-ring filter located
on the bottom of the water heater will need to be
cleaned periodically. Refer to the Maintenance of your
Water Heater section of this manual for information on
cleaning the base-ring filter.

Combustion Air Supply and Ventilation

Check for sufficient combustion air supply. Insufficient air

for the combustion of gas will result in the flame becoming

“lazy”, thereby allowing heat to build up in the combustion
chamber. This excessive heat will cause a thermal switch
on the door assembly to trip. Is the water heater installed
in a closet or other small, enclosed space? If so:

□ Are there openings for make-up air to enter and exit

the room/area?

□ Are the openings of sufficient size? Remember, if

there are other gas-fired or air-consuming appliances

in the same room, you need more make-up air. Refer

to the Location Requirements section of this water

heater manuai for specific requirements.

Fresh air not taken from areas that contain negative
pressure producing devices such as exhaust fans, dryers,

fireplaces, etc.

Is there a furnace/air handler in the same room space

as the water heater? If so, has a return air duct system
been attached that exits the room? If so, check for
leaks on the air duct system. If no air duct system is
present, correct immediately by contacting a local
Heating, Ventilation, Air-Conditioning & Refrigeration
(HVAC-R) authorized service provider.

Fresh air supply free of corrosive elements and

flammable vapors.

Fresh air openings sized correctiy with consideration

given to the blocking effect of louvers and grilles.

Ductwork is the same cross-sectional area as the

openings.

Vent Pipe System

Check for proper drafting at the water heater draft hood.
Refer to the “Checking the Draft” section of this manual for
the test procedure. If the procedure shows insufficient draft
is present, please check the following.

Draft hood properly installed.

Vent connectors securely fastened with screws and
supported properly to maintain six inch clearance.

Vent connector made of approved material and sized
correctly.

Vent pipe system installed according to all local and
state codes or, in the absence of local and state codes,
the “National Fuel Gas Code”, ANSI Z223.1(NFPA
54)-current edition.

Flue baffle properly positioned in the flue tube.

Check the vent system for restrictions/obstructions
and check the vent termination height. Refer to the
Combustion Air and Ventilation section of this water
heater manual for specific requirements.

Recheck for sufficient combustion air supply.

Water System Piping

Temperature and pressure relief valve properly installed

with a discharge line run to an open drain and protected
from freezing.

□ All piping properly installed and free of leaks.

Heater completely filled with water.

Closed system pressure build-up devices installed.

Tempering valve (when applicable) installed per

manufacturer’s instructions (See Water Temperature
Regulation section).

Gas Supply and Piping

Gas type is the same as that listed on the water heater
rating plate.

Gas line equipped with shut-off valve, union, and drip
leg.

Use pipe joint compound or teflon tape marked as being
resistant to the action of petroleum [Propane (L.P.)]

gases.

□ Adequate pipe size and approved pipe material.

□ An approved noncorrosive leak detection solution used

to check all connections and fittings for possible gas

leaks. Correct any leak found.

19