Troubleshooting guide – Bryant 463AAC008BA User Manual
Page 16
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Troubleshooting Guide
Frequently, a problem is minor and a service call may not be necessary, use this troubleshooting guide fort
possible solution If the unit continues to operate improperly, call 1-800-428-4326 for assistance, or call you
closest dealer
PROBLEM
POSSIBLE CAUSE
SUGGESTED SOLUTION
Air conditioner will
not operate
No power to the unit
Check connection of power cord to
power source.
Check fuse or circuit breaker
Set FAN CONTROL to position other
than "OFF"
Inefficient or no cooling
Dirty air filter
Inappropriate capacity
for application
Blocked air flow
Power interruption, settings
change too quickly, or
compressor overload tripped
Clean or replace air fitter
Check with dealer to determine proper unit
capacity for application
Remove obstruction from grill or
outdoor louvers
Let fan run to restart compressor
{in approximately 10 minutes )
Noisy unit
Loose parts
Inadequate support
Tighten loose parts
Provide additional support to unit
Odors
Formation of mold, mildew, or
algae on wet surfaces
Remove drain plug and drain base pan
Replace drain plug
Clean unit thoroughly
Water dripping outside
Condensation run-off is normal
during hot and humid weather
Add flexible tubing to redirect water flow,
see (Fig 23 Page 12)
Water dripping inside
Unit is not properly angled to
allow water to drain outside
Unit must be installed on an angle for prope
condensation run-off Check the unit and
make adjustments
Ice or frost build-up
Low outside temperature
Unit air filter is dirty
When outdoor temperature is approximately
65T or below, frost may form when unit is in
cooling mode Switch unit to FAN (only)
operation until frost melts
Remove and clean filter
NOTE:
1 !f circuit breaker is tripped repeatedly, or fuse is blown more than once, contact a qualified technician
-