Basement, Furnace, Counterflow – Bryant Gas Fired Forced Air 394 User Manual
Page 3: Basement furnace, Counterflow furnace, Tboth sides
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

BASEMENT
FURNACE
Model
No.
A.G.A. Ratings BTU/HR
Natural Propane
A
В
С
D
Е
F
G
Н
J
к
Gas Connection
Sizes
Filters
Approx.
Shipping
Weight
(Lb.)
Input
Bonnet
Capacity
Input
Bonnet
Capacity
Nat.
Prop.
50-394
50,000
40,000
50,000
40,000
46
40'Л
1654
иУв
20
2'Л
2%
4"
533Уа
З'Л
54
Уа
14 X 25 X 1
166
80-394
80,000
64,000
75,000
60,000
46
40'Л
1б'Л
иУв
20
2'Л
2%
4"
533Уа
з'Л
54
Уа
1 4 X 25 X 1
192
100-394
100,000
80,000
100,000
80,000
46
40'Л
18Й
1 бУа
20
2Уг
2%
5"
|ЗЗУа
з'Л
'Л
Уа
1 6 X 25 X 1
213
125-394
125,000
100,000
125,000
100,000
46
40 Уг
20Й
1 ^Уа
20
2'Л
2%
5"
533Уа
З'Л
54
Уа
20 X 25 X 1
238
137-394
137,500
n 0,000
Not available
46
40’Л
2054
13Н
20
2'Л
2%
5 "
t33ya
З'Л
Уа
Уа
20 X 25 X 1
240
165-394
165,000
132,000
150,000
120,000
51
43 54
2 8'/4
26Уа
17%
4'Л
4'Л
Ь"
ЗО'Уа
4
Уа
Уа
Two 1 6 X 25 X 1
343
190-394
190,000
152,000
175,000
140,000
51
4314
36'А
34Уа
17%
4'Л
5
2-5"
ЗО'Уа
4
Уа
Уа
Two 1 6 X 25 X 1
428
220-394
220,000
176,000
200,000
160,000
51
43 54
3654
34Уа
17%
4'Л
5
2-5"
30'5/й
4
Уа
Уа
Two 1 6 X 25 X 1
428
Ratings are certified for altitudes to 2,000 feet for all gases. Ratings for altitudes over 2,000 feet are 4% less for each 1,000 feet above sea level.
Return air compartment shipped separately, knocked down.
tBoth Sides.
COUNTERFLOW
FURNACE
1 8 % 1 0 0 S I Z E
1 6 % . 5 0 & 8 0 S I Z E
It OUTLET
TYP'E "C"
dimensions
L
TLET I
Model
No.
A.G.A. RATINGS BTU/HR
A
В
C
0
E
F
G
H
J
К
*
L
GAS CON.
SIZES
Filters
Approx.
Shipping
Weight
(Lb.)
Natural Pro pane
Input
Bonnet
Capacity
Input
Bonnet
Capacity
Nat.
Prop.
50-394
50,000
40,000
50,000
40,000
75
26
16Й
14%
2%
4"
12%
22%
I'/a
ЗУа
t33ya
Уа
Уа
1 6 x 2 0 x 1
1 6 6
80-394
80,000
64,000
75,000
60,000
75
26
16(4
14%
2%
4"
12%
22%
1Уа
ЗУа
t33ya
Уа
Уа
16 X 20 X 1
185
100-394
100,000
80,000
100,000
80,000
75
26
18У4
16%
2%
5"
14%
22%
I'/a
ЗУа
ТЗЗУа
Уа
Уа
Two 1 0 X 20 X 1
210
125-394
125,000
100,000
125,000
1 00,000
75
26
20(4
18%
2%
S"
18%
22%
I'/a
ЗУа
t33ys
Уа
Уа
Two 1 4 X 20 X 1
235
137-394
137,500
1 10,000
Not available
75
26
20%
18%
2%
5"
18%
22%
I'/a
ЗУа
|ЗЗУа
Уа
Уа
Two 1 4 X 20 X 1
237
165-394
165,000
132,000
150,000
1 20,000
80
28%
28
26%
4'/a
6"
25%
23%
1Уа
4
301 У.
Уа
Уа
Two 1 6 X 20 X 1
325
190-394
190,000
152,000
175,000
1 40,000
80
28%
36%
34%
5
(2) 5"
33%
23%
1Уа
4
ЗО'У.
Уа
Уа
Two 20 X 20 X 1
405
220-394
220,000
176,000
200,000
1 60,000
80
28%
36%
34%
5
(2) 5”
33%
23%
1Уа
4
ЗО'Уа
Уа
Уа
Two 20 X 20 X 1
405
*Add 114” when installed with base on combustible floor.
tBoth Sides.
**See above “CS” Drawing for Dimensions (50-80-100 Sizes Only).
39394D41