B. ENGINE START MEMORIZING FOR VEHICLES WITH MANUAL

TRANSMISSIONS

The system senses the neutral transmission position automatically and there

is no prior set-up required. The system in the standard transmission vehicle

operates a process that when you exit the vehicle It senses and memorizes

the neutral transmission position. If the vehicle is equipped with a automatic
transmission, this process is omitted.

1. While engine is running with ignition key, set the emergency brake and

place the transmission in the neutral position.

2. Before turning off the engine, press the button twice on the transmitter.

The LED indicator wilf flash 3 times to confirm it is entered.

3. Turn off the "Ignition Key" and remove it from the key cylinder.

The engine will continue running until the pre-programmed time elapsed

or a shutdown input is received.—

4. Exit the vehicle, close all doors.

The engine should still continue running, this is a normal operating

process.

5. Within 1 minute from the time of step 1, press the S button on the

transmitter to lock the doors.

6-1. If the engine shuts down immediately and the system is now ready

for next remote (or programmable) engine starts.

6-2. If the engine does not shut down immediately, the system has failed

in engine start memorize set up, repeat above process again.

If a door is opened after the above process, the prior memorization for

the next remote or programmed engine start sequence was delete and

the function shall not work until you repeat above process again.

Note: If the engine start memorize is set up, the dome light

supervision function will be temporarily by-passed.

C. TO OPERATE THE VEHICLE

WHILE RUNNING IN THE REMOTE START MODE:

To operate the vehicle while running in the remote start mode:

Insert the ignition key and turn it to the "ON" (not the start) position.

Press the brake pedal.

Note: If the brake pedal is pressed before the key is in the "ON"

position, the engine will shut down.

14

D. PIT-STOP FEATURE:

This feature allows the vehicle to remain running after the key has been

removed from the ignition switch. This feature is useful for occasions when

you wish to exit and lock the vehicle for short periods of time, but would

like to leave the engine running and the climate control

on.

1. Before turning off the engine, press the ^

button

twice on the transmitter

and the LED indicator will flash 3 times to confirm the program was
entered.

2. Turn the ignition key to the

OFF

position. (The engine will stay running.)

3. The engine will run until the pre-programmed time elapsed or a shutdown

input is received.

Note: For Standard Transmission Vehicles: Before pressing the ^

button, set the emergency brake first.

E. TURBO COOL-DOWN TIMER MODE:

(See

Alarm Feature "2 - 7"

Programming)

Turbo Cool Down timer mode keeps the engine running after arriving at

your destination for a programmable period of 1, 3 or 5 minutes. This allows
the system's run time to conveniently cool down the turbo after you have

left the vehicle. To activate:

1.

While engine is running, place the transmission in the park position and

set the emergency brake.

2.

Before turning off the engine, press and release the

3

and

^4^ buttons

at the same time.

— The parking light wills turn

on

to indicate the remote starter has entered

turbo cool down mode. —

3.

Turn the ignition key OFF and remove it from the key cylinder.

— The engine will remain running. —

4.

Exit and secure(lock) the vehicle.

— The engine will remain running until the pre-programmed time has
elapsed. -

F. TIMER / TEMPERATURE START:

This unit can be programmed to start and run the engine every

2 or 3

hours

or punctually at the same time the next morning, the engine will run

for the programmed running time and then shut down.

IMPORTANT:

Timer Start should be used only in open areas, never start

and run the vehicle in an enclosed space such as a garage or carport.