Counterflow, Furnace, Basement – Bryant Gas Air 393U User Manual
Page 3: Counterflow furnace, Basement furnace, 3 - 393u
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

EZD
G
AIR OUTLET
COUNTERFLOW
FURNACE
MODEL
NO.
A.G.A. RATINGS
BTU/HR
*
A
В
C
D
E
F
G
H
J
К
*
1
GAS CONNECTION
SIZES
FILTERS
APPROX.
SHIPPING
WEIGHT
(LB.)
INPUT
BONNET
CAPACITY
NAT.
MFD.
Prop.
50-393,
^0,000
40,000
75
26
16V4
143^
2%
4"
12%
22%
1%
2%
27%
%
'A
'A
16 X 20 X 1
166
**80-393
80,000
64,000
75
26
16'Л
14?4
2%
4"
12%
22%
1%
2%
27%
Vi
.'A
'A
16 X 20 X 1
185
100-393
100,000
80,000
75
26
1814
16%
3
5"
14%
22%
l'/2
2%
27%
'A
'A
'A
Two 10 X 20 X 1
210
125-393
1 25,000
1 00,000
75
26
20Й
18%
3
5"
18%
22%
1%
2%
27%
'Л
%
'A
Two 14 X 20 X 1
235
150-393
150,000
120,000
80
283Л
28
26%
5Ув
6"
25%
23%
2Ув
4
30%
%
%
%
Two 16 X 20 X 1
325
* Add 1 when installed with base on combustible fioor.
** For LP Gas, Model Designation 80-V-393, A.G.A. Input 75,000, Bonnet Capacity 60,000.
BASEMENT
FURNACE
MODEL
NO.
A.G.A.
ВТ
RATINGS
U/HR
A
В
c
D
E
F
G
H
J
К
GAS CONNECTION
SIZES
FILTERS
APPROX.
SHIPPING
WEIGHT
(LB.)
INPUT
BONNET
CAPACITY
NAT. MFD. Prop.
50-393
50,000
40,000
46
40%
16%
14%
20
2%
23%
4"
27%
2%
'A
'A
'A
14 X 25 X 1
166
*80-393
80,000
64,000
.46
40%
16%
14У,
20
2%
23%
4"
27%
23%
'A
'A
'A
14 X 25 X 1
192
100-393
1 00,000
80,000
46
40%
18%
16У,
20
2%
3
5"
27%
2%
'A
'A
'A
16 X 25 X 1
213
125-393
1 25,000
100,000
46
40%
20%
18Уа
20
2%
3
5"
27%
23%
'A
%
'A
20 X 25 X 1
238
150-393
150,000
120,000
51
43%
28%
26%
17%
4%
53/s
b"
30%
4
%
%
%
Two 1 6 X 25 X 1
343
175-393
175,000
140,000
51
43%
36%
34%
17%
4%
43%
2-5"
30%
4
3%
%
3%
Two 1 6 X 25 X 1
428
200-393
200,000
160,000
51.
43%
36%
34%
173%
4%
43%
2-5"
30%
4
%
3% •
•%
Two 1 6 X 25 X 1
428
250-393
250,000
200,000
Sizes 250 through 400 are multiples of sizes 125, 150, 1.75, and 200 respectively. Refer to the dimensions
of the smaller sizes to obtain overall dimensions for the larger sizes. Provide clearance dimensions between
units for gas service and casing expansion. Refer to tnstallation instructions for minimum clearances.
300-393
300,000
240,000
350-393
350,000
280,000
400-393
400,000
320.000
Ratings ore approved for altitudes to
less for each 1,000 feet above sea
* For LP Gas, Model Designation 80-V-
2,000 feet for all gases. Ratings for altitudes over 2,000 feet are 4%
level.
Return air compartment shipped separately, knocked down.
393, A.G.A. Input 75,000 Bonnet Capacity 60,000.
■ 3 -
393U