EZD

G

AIR OUTLET

COUNTERFLOW

FURNACE

MODEL

NO.

A.G.A. RATINGS

BTU/HR

*
A

В

C

D

E

F

G

H

J

К

*

1

GAS CONNECTION

SIZES

FILTERS

APPROX.
SHIPPING

WEIGHT

(LB.)

INPUT

BONNET

CAPACITY

NAT.

MFD.

Prop.

50-393,

^0,000

40,000

75

26

16V4

143^

2%

4"

12%

22%

1%

2%

27%

%

'A

'A

16 X 20 X 1

166

**80-393

80,000

64,000

75

26

16'Л

14?4

2%

4"

12%

22%

1%

2%

27%

Vi

.'A

'A

16 X 20 X 1

185

100-393

100,000

80,000

75

26

1814

16%

3

5"

14%

22%

l'/2

2%

27%

'A

'A

'A

Two 10 X 20 X 1

210

125-393

1 25,000

1 00,000

75

26

20Й

18%

3

5"

18%

22%

1%

2%

27%

%

'A

Two 14 X 20 X 1

235

150-393

150,000

120,000

80

283Л

28

26%

5Ув

6"

25%

23%

2Ув

4

30%

%

%

%

Two 16 X 20 X 1

325

* Add 1 when installed with base on combustible fioor.

** For LP Gas, Model Designation 80-V-393, A.G.A. Input 75,000, Bonnet Capacity 60,000.

BASEMENT

FURNACE

MODEL

NO.

A.G.A.

ВТ

RATINGS

U/HR

A

В

c

D

E

F

G

H

J

К

GAS CONNECTION

SIZES

FILTERS

APPROX.
SHIPPING

WEIGHT

(LB.)

INPUT

BONNET

CAPACITY

NAT. MFD. Prop.

50-393

50,000

40,000

46

40%

16%

14%

20

2%

23%

4"

27%

2%

'A

'A

'A

14 X 25 X 1

166

*80-393

80,000

64,000

.46

40%

16%

14У,

20

2%

23%

4"

27%

23%

'A

'A

'A

14 X 25 X 1

192

100-393

1 00,000

80,000

46

40%

18%

16У,

20

2%

3

5"

27%

2%

'A

'A

'A

16 X 25 X 1

213

125-393

1 25,000

100,000

46

40%

20%

18Уа

20

2%

3

5"

27%

23%

'A

%

'A

20 X 25 X 1

238

150-393

150,000

120,000

51

43%

28%

26%

17%

4%

53/s

b"

30%

4

%

%

%

Two 1 6 X 25 X 1

343

175-393

175,000

140,000

51

43%

36%

34%

17%

4%

43%

2-5"

30%

4

3%

%

3%

Two 1 6 X 25 X 1

428

200-393

200,000

160,000

51.

43%

36%

34%

173%

4%

43%

2-5"

30%

4

%

3% •

•%

Two 1 6 X 25 X 1

428

250-393

250,000

200,000

Sizes 250 through 400 are multiples of sizes 125, 150, 1.75, and 200 respectively. Refer to the dimensions
of the smaller sizes to obtain overall dimensions for the larger sizes. Provide clearance dimensions between

units for gas service and casing expansion. Refer to tnstallation instructions for minimum clearances.

300-393

300,000

240,000

350-393

350,000

280,000

400-393

400,000

320.000

Ratings ore approved for altitudes to
less for each 1,000 feet above sea

* For LP Gas, Model Designation 80-V-

2,000 feet for all gases. Ratings for altitudes over 2,000 feet are 4%

level.

Return air compartment shipped separately, knocked down.