DETAILED COOLING CAPACITIES*

Evaporator

CONDENSER ENTERING AIR TEMPERATURES °F

Air

85

95

105

115

E

Capacity

Totai

Capacity

Totai

Capacity

Totai

Capacity

Total

CFM

W

MBtuhf

System

MBtuhf

System

MBtuhf

System

MBtuhf

System

B

Totai

Sens:(

KW**

Totai

Sensf

KW**

Totai

Sensf

KW**

Totai

Sensf

KW**

544B024 Outdoor Section With 517EN030 Indoor Section

72

26.3

13.1

2.41

24.8

12.6

2.60

23.3

12.0

2.78

21.8

11.5

2.95

800

67

23.9

16.8

2.36

22.5

16.2

2.54

21.1

15.7

2.71

19.8

15.1

2.87

62

21.7

20.3

2.32

20.5

19.6

2.48

19.3

18.9

2.65

18.2

18.1

2.81

57

21.2

21.2

2.31

20.2

20.2

2.48

19.2

19.2

2.64

18.2

18.2

2.81

72

26.6

13.6

2.46

25.1

13.1

2.65

23.6

12.5

2.83

22.0

12.0

3.01

900

67

24.2

17.7

2.41

22.8

17.1

2.59

21.4

16.6

2.77

20.0

16.0

2.93

62

22.2

21.4

2.37

20.9

20.6

2.54

19.8

19.8

2.71

18.7

18.7

2.88

57

21.9

21.9

2.37

20.8

20.8

2.54

19.8

19.8

2.71

18.7

18.7

2.88

72

26.9

14.1

2.51

25.3

13.5

2.70

23.8

13.0

2.88

22.2

12.4

3.07

1000

67

24.5

18.5

2.46

23.0

17.9

2.64

21.6

17.3

2.82

20.1

16.8

2.99

62

22.5

22.3

2.43

21.4

21.4

2.60

20.2

20.2

2.77

19.1

19.1

2.95

57

22.5

22.5

2.42

21.4

21.4

2.60

20.2

20.2

2.77

19.1

19.1

2.95

Multipliers for Determining the Performance With Other Indoor Sections

Indoor

Section

Size

Cooiing

indoor

Section

Size

Cooiing

Capacity

Power

Capacity

Power

506 B

030

0.98

0.99

517E

024

0.94

1.00

036

1.00

1.00

030

1.00

1.00

508A

024

1.00

0.97

036

1.01

1.02

513C

024

0.96

1.00

519D/509A

024

1.00

0.99

030

1.00

1.02

030

1.01

0.99

030X

1.01

0.99

544B030 Outdoor Section With 517EN036 Indoor Section

1000

72
67

62
57

33.0
30.0

27.4
26.6

16.4

21.0

25.4
26.6

3.30
3.20
3.10
3.07

31.1
28.2
25.8
25.4

15.7

20.3
24.6
25.4

3.48

3.37
3.28
3.26

29.1
26.4
24.3
24.1

15.0
19.5

23.7
24.1

3.67
3.55
3.46
3.45

27.2
24.6
22.7

22.7

14.3
18.8

22.6
22.7

3.87
3.74 '
3.64
3.64

72

33.4

17.0

3.38

31.4

16.3

3.56

29.4

15.6

3.75

27.4

14.9

3.95

1125

67

30.4

22.1

3.27

28.6

21.4

3.45

26.8

20.6

3.63

24.9

19.9

3.82

62

27.9

26.8

3.18

26.3

25.8

3.36

24.8

24.8

3.54

23.3

23.3

3.74

57

27.5

27.5

3.17

26.2

26.2

3.35

24.8

24.8

3.54

23.4

23.4

3.74

72

33.7

17.6

3.45

31.6

16.9

3.63

29.6

16.1

3.82

27.5

15.4

4.02

1250

67

30.8

23.1

3.35

28.9

22.4

3.52

27.0

21.6

3.71

25.1

20.9

3.90

62

28.4

27.9

3.26

26.8

26.8

3.44

25.4

25.4

3.63

23.8

23.8

3.83

57

28.2

28.2

3.26

26.8

26.8

3.44

25.3

25.3

3.63

23.9

23.9

3.83

Multipliers for Determining the Performance With Other Indoor Sections

indoor

Section

Size

Cooiing

Indoor

Section

Size

Cooiing

Capacity

Power

Capacity

Power

506B

030

0.97

0.98

517E

030

0.97

0.99

036

1.00

0.99

036

1.00

1.00

042

1.00

0.99

042

1.02

1.01

508A

036

0.99

0.97

519C

042

1.03

1.00

510B

030

0.97

0.98

519C &

520B042

042

1.03

1.00

036

1.00

0.99

509A/519D

030X

0.98

0.98

513C

030

0.99

1.02

036

0.99

0.99

519D

030

0.98

0.98

036X

0.99

0.99

544B036 Outdoor Section With 517E/GN042 indoor Section

1200

72
67
62

57

41.1
37.4
34.3
33.4

20.7
26.4
31.9
33.4

3.75
3.64

3.55
3.52

38.8
35.4
32.3
31.8

19.8

25.6
30.8
31.8

4.02
3.90
3.79

3.77

36.3
33.1
30.3
30.0

18.9

24.6
29.7
30.0

4.28
4.14
4.02
4.01

33.8
30.8
28.4
28.4

18.0

23.7
28.3
28.4

4.54
4.38
4.26
4.26

72

41.6

21.4

3.83

39.2

20.5

4.10

36.7

19.7

4.36

34.1

18.8

4.62

1350

67

38.1

27.9

3.73

35.8

26.9

3.98

33.5

26.0

4.23

31.1

25.1

4.47

62

34.9

33.6

3.63

32.9

32.4

3.88

30.9

30.9

4.12

29.1

29.1

4.37

57

34.5

34.5

3.62

32.8

32.8

3.87

31.0

31.0

4.12

29.2

29.2

4.37

72

42.2

22.3

3.91

39.4

21.3

4.17

36.9

20.4

4.44

34.3

19.5

4.70

1500

67

38.4

29.2

3.80

36.1

28.2

4.06

33.7

27.3

4.31

31.3

26.3

4.55

62

35.6

35.2

3.72

33.7

33.7

3.97

31.8

31.8

4.23

29.9

29.9

4.48

57

35.4

35.4

3.72

33.7

33.7

3.97

31.8

31.8

4.22

29.9

29.9

4.47

Multipliers for Determining the Performance With Other Indoor Sections

indoor

Section

Size

Cooling

Indoor

Section

Size

Cooiing

Capacity

Power

Capacity

Power

506B

036

0.98

0.99

519C

042

0.99

0.99

042

0.98

0.99

519C &520B

042

0.99

0.99

048

0.99

0.99

519D/509A

036

0.97

0.99

508A

036

0.94

0.97

042

0.99

0.99

510B

036

0.97

0.98

042X

0.99

0.99

048

1.02

1.01

042C

0.99

1.00

517E

036

0.96

1.01

043

0.99

1.00

042

1.00

1.00

043X

0.99

1.00

043

1.00

1.01

519D

036X

0.97

0.99

048

1.01

1.01