SPECIFICATIONS
MODEL
544B018
SERIES DATA
A
PERFORMANCE DATA
ARI Noise Rating Number*
7.6 _ I
508A
024
—
—
—
_
—
—
_
—
—
510B
—
024
—
—
—
—
—
513C
—
018
024
—
—
—
__
—
516A
—
—
_
__
018
024
—
—
—
517E
—
— ■
—
—
__
018
024
—
—
519D/509A
—
—
—
_
—
—n—1
—
__
018
024
Rated Cooling Capacity -47“F
18700
18900
18000
18500
18700
18900
18600
19000
18200
18700
HSPF
6.85
6.95
6.70
6.90
6.85
6.85
6.65
6.85
6.65
6.90
Rated Cooling Capacity Btuhf
17700
17300
17000
17600
17600
17800
16700
17200
17000
17700
SEER
9.50
9.35
9.35
9.45
9.30
9.50
9.00
9.15
9.25
9.50
SEER w/TDR
10.00
9.85
9.90
9.95
9.80
10.00
9.45
9.65
9.75
10.00
MODEL
544B024
SERIES DATA
A
PERFORMANCE DATA ' •
ARI Noise Rating Number*
1_____________________ 7.6 1
506 B
030
036
—
—
—
—
—
—
—
—
__
513C
—
_
024
030
—
—
—
—
—
517E
—
—
—
024
030
036 ’
------------------ 1
—
—
509A/519D
—
—
—
—
—
—
024
030
030X
—
508A
—
—
—
—
—
—
—
—
024
Rated Cooling Capacity -47°F
25000
25600
24800
25400
25400
25400
25400
25000
25200 1
25200
25200
HSPF
1 6.70
6.95
6.60
6.75
6.70
6.70
6.75
6.80
6.85
6.85
6.60
Rated Cooling Capacity Btuht
22400
22800
22000
22800
21400
22800
23000
22800
23000
23000
22800
SEER
9.60
9.60
9.30
9.50
9.00
9.50
9.50
9.50
9.65
9.65
9.50
SEER w/TDR
10.00
1 10.30
9.70
1 9.90
9.40
9.90
9.90
9.90
10.10
10.10
9.90
MODEL
544B030
SERIES DATA
A
PERFORMANCE DATA
ARI Noise Rating Number*
1_________________________ . 7.6 1
505B
030
036
042
_
—
—
—
—
~
—
—
—
—
—
—
—
519D
—
-
—
030
036X
—
—
—
-
—
—
-
_
—
510B
—
—
—
—
—
030
036
—
—
—
—
—
—
—
—
508A
—
—
—
—
__ j
—
~ i
035
—
—
—
—
—
1
—
—
513C
—
-
-
—
—
-
—
030
—
-
—
—
—
-
-
517E
—
-
—
—
—
—
—
—
—
030
036
042
—
—
—
519C
-
-
-
—
-
- ,
—
—
_
1
—
-
—
042
—
—
-
519G with 520B042
—
1 —
—
—
—
_ 1
—
—
—
1
_
. —
-----------------1
_
042
— ■ ■
509Aor519D
—
—
—
~
-
-
—
—
-
—
-
-
—
_
030X
036
Rated Cooling Capacity - 47°Ft
30,600
31,800
31,800
31,200
31,400
31,200
31,600
30,600
31,600
31,200
31,600
32,200
31,800
31,800
31,200
31,400
HSPF
6.90
7.15
7.15
7.00
7.10
6.90
7.05
7.15
6.95
6.85
7.05
7.20
7.20
7.20
7.00
7.10
Rated Cooling Capacity Btuht
27,600
28,600
28,600
28,000
28,400
27,800
28,600
28,400
28,200
27,600
28,600
29,200
29,400
29,400
28,000
28,400
SEER
9.10
9.25
9.25
9.30
9.40
9.20
9.35
9.30
9.00
9.00
9.20
9.35
9.35
9.25
9.30
9.40
SEER w/TDR
9.50
9.70
9.60
9.70
9.80
9.60
9.75
9.50
9.40
9.25
9.60
9.80
9.75
9.70
9.70
9.80
MODEL
544B036
SERIES DATA
PERFORMANCE DATA
ARI Noise Rating Number*
7.6
506B
036
042
048
508A
—
—
—
036
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
510B
—
—
—
—
036
048
517E
—
—
—
—
—
—
036
042
043
048
—
—
—
_
—
— ■
—
519C
—
—
—
—
—
—
—
—
—
—
042
—
—
—
—
—
519C-F520B042
—
—
—
—
—
-
—
—
—
—
—
042
—
—
—
—
—
—
519D/509A
036
042
042X
042C
043
043X
_
519D
036X
Rated Cooling Capacity -47°Ft
37600 37600 38000 36800 37400 38500 37600 38000 38000 38500 38000 38000 37200 37800 37800 37200 37400 37400 37200
HSPF
6.85
6.85
6.95
6.70
6.85
7.10
6.70
7.00
7.00
7.10
6.90
6.90
6,90
7.00
7.00
7.05
7.10
7.10
6.90
Rated Cooling Capaoity Btuht
35000 35000 35400 33800 34600 36400 34400 35800 35800 36200 35600 35600 34600 35400 35400 35400 35500 35600 34600
SEER
9.55
9.55
9.65
9.30
9.55
9.80
9.25
9.65
9.45
9.75
9.65
9.60
9.55
9.75
9.75
9.75
9.80
9.80
9.55
SEER w/TDR
10.00
10.00
10.15
9.50
10.00
10.25
9.65
10.05
9.80
10.25
10.15
—
10.00
10.20
10,20
10.20
10.25 10.25
10.00
EER30
8.95
8.95
9.05
8.80
8.95
9,15
8,65
9.00
9.10
9,10
9.00
9.00
8,90
9.00
9.00
9.00
9.10
9.10
8,90
*lf other than 60°C copper wire is used, size can be determined from unit ampacity given in above tabie and applicabie tabie of National Electric
Code. Wire size selected must have current capacity not less than that of copper wire specified and must not create a voltage drop between service
panel and unit in excess of 2% of unit rated voltage.
tThe factory refrigerant charge is sufficient for systems requiring up to 30-feet of interconnecting tubing. For tubing lengths other than 30-feet, see
Installation Instructions for additional refrigerant requirements.
TSingle-phase units may use fuses or HACR-type circuit breakers (U.S. only) of same size as noted.
HP-56