SPECIFICATIONS
ARl Noise Rating Number*
5068
519C + 520B042
Rated Cooling Capacity -47®Ft
Rated Cooiing Capacity Btuhf
ARl Noise Rating Number*
5066
048
060 061
048
5108
048
060
048
049
060
063
519C
060
519C + 520B042
048
060
519D/509A
048X
519D
048C
049
Rated Cooling Capacity -47°Ft
46500 46000 46000 47500 46000 46000
46500 46000 47000 46500 46000 48000 46500 46500 45500 46000
HSPF
6.65
6.85
6.70
6.90
7,00
7.00
7.00
7.00
6.75
6.90
7.05
Rated Cooling Capacity Btuhf
44000 44000 44000 46000
45000
44500 42500 44500 44500 46000 46000 48000
44500 46000
SEER
9.20
9.10
9.25
9.00
9.20
9.05
9.00
9.40
9.65
9.75
9.40
9.40
9.50
SEER w/TDR
9.35
9.50
9.45
9.50
9.55
9.30
9.50
9.30
9.30
9.50
9.35
3.50
9.35
9.70
10.05 9.70
9.70
9.85
EER 30
8.10
8.50
8.35
8.20
8.45
8.10
8.25
7.95
8.35
8.55
8.70
8.35
MODEL
544B060
SERIES
A
PERFORMANCE DATA
ARl Noise Rating Number *
1_______________________________ 7-6 . .. 1
506B
060
061
—
—
—
—
—
—
—
517E
—
—
060
062
063
—
—
—
—
509A/519D
—
_
—
—
057C
060
061
—
519C
_ i
—
— 1
—
— 1
— i
—
— i
060
Rated Cooling Capacity -47°Ff
55500
56500
57000
57000
58000
55500
57000
56000
55000
HSPF
6.70
6.85
6.75
6.85
6.85
6.75
6.85
6.85
6.70
Rated Cooling Capacity Btuhf
51500
54500
52500
53000
54500
52000
53000
54500
50500
SEER w/TDR
8.90
9.20
8.30
8.70
9.00
9.00
9.00
9.20
9.00
DETAILED COOLING CAPACITIES*
Evaporator
CONDENSER ENTERING AIR TEMPERATURES °F
Air
85
95
105
115
E
Capacity
Total
Capacity
Totai
Capacity
Totai
Capacity
Total
CFM
W
MBtuhf
System
MBtuhf
System
MBtuhf
System
MBtuhf
System
B
Total
Sensf
KW**
Totai
Senst
KW**
Totai
Sensf
KW**
Totai
Sensf
KW**
544B018 Outdoor Section With 517EN024 indoor Section
72
19.8
9.93
1.78
18.7
9.55
1.89
17.7
9.16
1.99
16.5
8.76
2.10
600
67
18.0
■12.7
1.73
17.0
12.3
1.83
16.0
11.9
1.93
14.9
11.5
2.02
62
16.3
15.3
1.68
15.4
14.8
1.77
14.5
14.3
1.87
13.7
13.7
1.97
57
15.9
15.9
1.67
15.2
15.2
1.76
14.4
14.4
1.87
13.7
13.7
1.96
72
20.1
10.3
1.83
19.0
9.94
1.93
17.9
9.54
2.03
16.7
9.14
2.14
675
67
18.2
13.4
1.77
17.2
13.0
1.87
16.1
12.6
1.97
15.1
12.1
2.07
62
16.6
16.1
1.72
15.8
15.6
1.82
14.9
14.9
1.92
14.1
14.1
2.02
57
16.5
16.5
1.72
15.7
15.7
1.82
14.9
14.9
1.92
14.1
14.1
2.02
72
20.3
10.7
1.87
19.2
10.3
1.97
18.0
9.90
2.07
16.8
9.49
2.17
750
67
18.4
14.0
1.81
17.4
13.6
1.91
16.3
13.2
2.01
15.2
12.8
2.11
62
17.0
16.9
1.77
16.1
16.1
1.87
15.3
15.3
1.97
14.4
14.4
2.07
57
16.9
16.9
1.76
16.1
16.1
1.87
15.3
15.3
1.97
14.4
14.4
2.07
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Cooling
Indoor
Section
Size
Cooiing
Capacity
Power
Capacity
Power
508A
024
1.03
0.96
517E
018
0.97
0.99
51 OB
024
1.01
0.98
024
1.00
1.00
513C
018
0.99
0.96
519D/509A
018
0.98
0.99
024
1.02
0.97
024
1.03
0.99
516A
018
1.02
1.00
024
1.03
1.00
*Detailed cooling capacities are based on indoor and outdoor unit at the same elevation and connected by 25 feet of tubing. If other than 25
feet of tubing is used and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.
tTotal and sensible capacities are net capacities. Blower motor heat has been subtracted.
^Sensible capacities shown are based on 80°F entering air at the indoor coil. For sensible capacities at other than 80°F, deduct 835 Btuh per
1000 Cfm of indoor coil air for each degree below80°F, or add 835 Btuh per 1000 Cfm of indoor coil air per degree above 80°F.
**Unit KW is total of indoor and outdoor unit KW’s.
HP-57