SPECIFICATIONS

ARl Noise Rating Number*

5068

519C + 520B042

Rated Cooling Capacity -47®Ft

Rated Cooiing Capacity Btuhf

ARl Noise Rating Number*
5066

048

060 061

048

5108

048

060

048

049

060

063

519C

060

519C + 520B042

048

060

519D/509A

048X

519D

048C

049

Rated Cooling Capacity -47°Ft

46500 46000 46000 47500 46000 46000

46500 46000 47000 46500 46000 48000 46500 46500 45500 46000

HSPF

6.65

6.85

6.70

6.90

7,00

7.00

7.00

7.00

6.75

6.90

7.05

Rated Cooling Capacity Btuhf

44000 44000 44000 46000

45000

44500 42500 44500 44500 46000 46000 48000

44500 46000

SEER

9.20

9.10

9.25

9.00

9.20

9.05

9.00

9.40

9.65

9.75

9.40

9.40

9.50

SEER w/TDR

9.35

9.50

9.45

9.50

9.55

9.30

9.50

9.30

9.30

9.50

9.35

3.50

9.35

9.70

10.05 9.70

9.70

9.85

EER 30

8.10

8.50

8.35

8.20

8.45

8.10

8.25

7.95

8.35

8.55

8.70

8.35

MODEL

544B060

SERIES

A

PERFORMANCE DATA

ARl Noise Rating Number *

1_______________________________ 7-6 . .. 1

506B

060

061

517E

060

062

063

509A/519D

_

057C

060

061

519C

_ i

— 1

— 1

— i

— i

060

Rated Cooling Capacity -47°Ff

55500

56500

57000

57000

58000

55500

57000

56000

55000

HSPF

6.70

6.85

6.75

6.85

6.85

6.75

6.85

6.85

6.70

Rated Cooling Capacity Btuhf

51500

54500

52500

53000

54500

52000

53000

54500

50500

SEER w/TDR

8.90

9.20

8.30

8.70

9.00

9.00

9.00

9.20

9.00

DETAILED COOLING CAPACITIES*

Evaporator

CONDENSER ENTERING AIR TEMPERATURES °F

Air

85

95

105

115

E

Capacity

Total

Capacity

Totai

Capacity

Totai

Capacity

Total

CFM

W

MBtuhf

System

MBtuhf

System

MBtuhf

System

MBtuhf

System

B

Total

Sensf

KW**

Totai

Senst

KW**

Totai

Sensf

KW**

Totai

Sensf

KW**

544B018 Outdoor Section With 517EN024 indoor Section

72

19.8

9.93

1.78

18.7

9.55

1.89

17.7

9.16

1.99

16.5

8.76

2.10

600

67

18.0

■12.7

1.73

17.0

12.3

1.83

16.0

11.9

1.93

14.9

11.5

2.02

62

16.3

15.3

1.68

15.4

14.8

1.77

14.5

14.3

1.87

13.7

13.7

1.97

57

15.9

15.9

1.67

15.2

15.2

1.76

14.4

14.4

1.87

13.7

13.7

1.96

72

20.1

10.3

1.83

19.0

9.94

1.93

17.9

9.54

2.03

16.7

9.14

2.14

675

67

18.2

13.4

1.77

17.2

13.0

1.87

16.1

12.6

1.97

15.1

12.1

2.07

62

16.6

16.1

1.72

15.8

15.6

1.82

14.9

14.9

1.92

14.1

14.1

2.02

57

16.5

16.5

1.72

15.7

15.7

1.82

14.9

14.9

1.92

14.1

14.1

2.02

72

20.3

10.7

1.87

19.2

10.3

1.97

18.0

9.90

2.07

16.8

9.49

2.17

750

67

18.4

14.0

1.81

17.4

13.6

1.91

16.3

13.2

2.01

15.2

12.8

2.11

62

17.0

16.9

1.77

16.1

16.1

1.87

15.3

15.3

1.97

14.4

14.4

2.07

57

16.9

16.9

1.76

16.1

16.1

1.87

15.3

15.3

1.97

14.4

14.4

2.07

Multipliers for Determining the Performance With Other Indoor Sections

Indoor

Section

Size

Cooling

Indoor

Section

Size

Cooiing

Capacity

Power

Capacity

Power

508A

024

1.03

0.96

517E

018

0.97

0.99

51 OB

024

1.01

0.98

024

1.00

1.00

513C

018

0.99

0.96

519D/509A

018

0.98

0.99

024

1.02

0.97

024

1.03

0.99

516A

018

1.02

1.00

024

1.03

1.00

*Detailed cooling capacities are based on indoor and outdoor unit at the same elevation and connected by 25 feet of tubing. If other than 25

feet of tubing is used and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.

tTotal and sensible capacities are net capacities. Blower motor heat has been subtracted.
^Sensible capacities shown are based on 80°F entering air at the indoor coil. For sensible capacities at other than 80°F, deduct 835 Btuh per

1000 Cfm of indoor coil air for each degree below80°F, or add 835 Btuh per 1000 Cfm of indoor coil air per degree above 80°F.

**Unit KW is total of indoor and outdoor unit KW’s.

HP-57