When charging is necessary during heating season,

charge must be weighed in accordance with unit rating plate ± 0.6
oz/ft of 3/8-in. liquid line above or below 15 ft respectively.

EXAMPLE:

To calculate additional charge required for a 25–ft line set:

25 ft – 15 ft = 10 ft X 0.6 oz/ft = 6 oz of additional charge

Step 15—Final Checks

IMPORTANT:

Before leaving job, be sure to do the following:

1. Securely fasten all panels and covers.

2. Tighten service valve-stem caps to 1/12-turn past finger-tight.

3. Leave User’s Manual with owner. Explain system operation

and periodic maintenance requirements outlined in manual.

4. Fill out Dealer Installation Checklist and place in customer

file.

CARE AND MAINTENANCE

For continuing high performance and to minimize possible equip-
ment failure, periodic maintenance must be performed on this
equipment.

Frequency of maintenance may vary depending upon geographic
areas, such as coastal applications.