Fuel consumption (gph/ibs.ph), 6 specifications, 1 fuel requirements – Generac Power Systems 009600-4 User Manual
Page 8: 2 engine oil requirements, Specifications, Jk caution jk, Figure 1.1, Connection for 120 volts only
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
![background image](/manuals/720456/8/background.png)
GENERAL
INFORMATION
Section 1 - General Information
PRIMEPACT 66G and 66LP Recreational Vehicle Generators
Figure 1.1
-
Connection for 120 Volts Only
Fuel Consumption
(gph/ibs.ph)
Figure 1.2 - Connection for 120/240 Volts
1.6
SPECIFICATIONS
♦ 1.6.1
FUEL REQUIREMENTS
This generator is equipped with a gasoline fuel system
as standard equipment. Specific installations may pro
vide either a separate fuel tank for the generator, or the
generator may “share” the vehicle engine’s fuel tank.
Model
No Load
1/2 Load
Full Load
PrimePact 66G
0.33
0.59
0.99
PrimePact 66LP
0,47/2.01
0.85/3.62
1,66/7.05
NOTE
Some installations using a “shared” fuel tank may
have a generator fuel pickup tube that is shorter
than the vehicle engine’s pickup tube. Such an
arrangement causes the generator engine to “run
out of gas” while adequate fuel for the vehicle
remains in the tank.
To reduce lead and carbon deposits use high quality
UNLEADED
gasoline
with
the
generator.
Leaded
REGULAR grade gasoline is an acceptable substitute.
NOTE:
Using unleaded gasoline contributes to longer engine
valve life by reducing lead and carbon deposits.
------ Jk CAUTION Jk-----------
A
Generac does not recommend using any
gasoline containing alcohol (such as "gasohol").
If you use any gasoline containing alcohol, it
must not contain more than 10 percent ethanol,
and it must be removed from the generator
during storage. Do
NOT
use any gasoline
containing methanol. If you use gasoline with
alcohol, inspect more frequently for fuel leaks
and other abnormalities.
♦ 1.6.2 ENGINE OIL REQUIREMENTS_______________
Use only high quality detergent oil classified “For
Service SF” and with an oil viscosity rating of SAE
lOW-30 oil. Do not pour in any additives to the rec
ommended
oil.
Engine
crankcase
capacity
is
1.4
liters. See Section 3.2 on page 11 for oil level check
and filing procedures.
♦ 1.6.3 GENERATOR SPECIFICATIONS
SERIES
PRIMEPACT 66G
PRIMEPACT 66LP
Rotor RPM
3600
3600
Rotor Poles
2
2
Engine RPM
2700
2700
Rated Max. Continuous AC Output*
6600 watts (6.6 kW)
6200 watts (6.2 kW)
Voltage*
120
120
Rated Max. Continuous Current*
55.0 AC ampst
51.7 AC amps N
Phase
1
1
Frequency
60 Hertz
60 Hertz
Battery Charging Current (Max.)
2
amps (trickle charge)
2
amps (trickle charge)
Weight
213 pounds
216 pounds
Length
25 inches
25.75 inches
Width
18,5 inches
18.5 inches
Height
15.75 inches
15.75 inches
* All units are reconnectable to 120 and/or 240 volts, dual voltage output. Units are not listed per RVIA/ANSI when reconnected for dual voltage output
t Rated maximum continuous current at 240 volts is 27,5 amps,
N Rated maximum continuous current at 240 volts is 25,8 amps.
6 Generac* Power Systems, Inc.