Note, Il iff a, 3 sound insulating materials – Generac Power Systems 009600-4 User Manual
Page 26: 4 acoustics, 3 sound insulating materials 6.2.4 acoustics
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

INSTALLATION
Section 6 - installation
PRIMEPACT 66C and 66LP Recreational Vehicle Generators
•
If constructing
a
compartment, line the exterior
(underside) of the compartment floor with 26-gauge
galvanized steel.
•
All seams, splices and joints of the compartment
walls
(unless
vapor
tight
by
design)
should
be
caulked to prevent poisonous, flammable or explo
sive vapors from entering the vehicle interior,
NOTE;
Caulking must be done so that the caulking material
will stay in place permanently. Pressing such materi
als as putty tape onto joints and seams is not accept
able. A high quality silicone rubber base sealant is
recommended.
•
Holes and openings made in the compartment walls
to allow for the passage of electrical conduit, conduc
tors, hoses, cables, etc., into the vehicle living area
must be sealed vapor tight with silicone rubber base
sealant.
•
If flexible metal conduit is used, it must be sealed
internally at the end where it terminates inside the
compartment’s electrical junction box.
NOTE:
Flexible metal conduit, due to its unique construc
tion, is NOT vapor tight along its entire length.
•
Seams and joints of the galvanized steel (whether
used as a liner or for the compartment itself) must be
lapped and mechanically secured. Such seams may
be manufactured, welded, bolted, riveted or screwed.
Manufactured lock seams are shown in Figure 6.6.
Installer constructed compartments typically utilize a
standard lap joint.
Figure 6.6
-
Types of Lock Seams
IL Iff a
LOCKED STANDING
H
I
*
1
OFF SI
DOUBLE LOCK DOUBLE!
r
WHE LOCH
STAKDARD LAP JOINT
After the compartment has been metal lined and
vapor sealed, line the compartment interior walls and
ceiling with an approved, nonflammable sound insu
lating material. See Section 6.2.3.
A
DANGER
Do not install any flammable material directly
above or around the compartment. Heat,
transferred through the compartment structure,
may be sufficient to ignite, char or discolor
seat cushions, fiberboard and other flammable
materials. You may need to use approved
nonflammable insulating materials in high
temperature areas.
♦ 6.2.3 SOUND INSULATING MATERIALS______________
Once installers have determined that a compartment is
properly constructed and metal lined, they can add
acoustical material. This may include additional sealant
or insulating material, to reflect noise away from the
vehicle interior.
Sound insulating materials should be of a nonflamma
ble type. One excellent insulating material is a 1 -inch
(25 mm) thick fiberglass having a 2-pound density.
When fiberglass is used, its coated side should face
toward the compartment interior.
DANGER
A Do not install sound insulation or any absorbent
material on the compartment floor interior. Such
materials will become soaked with combustible or
explosive vapors and liquids and will become a
fire hazard.
Using a combination of sound insulating materials can
often reduce noise more effectively than a single mater
ial. For example, a sheet of lead or visco-elastic materi
al, along with a layer of other acoustical material, is
more effective than when a single material is used.
• 6.2.4 ACOUSTICS
•
For additional noise abatement, the installer may wish
to consider the following:
• Using special sound insulating materials.
• Construction of a special noise abatement compart
ment.
NOTE:
Any method used to reduce noise must not adverse
ly affect the flow of cooling and ventilating air into or
out of the compartment.
In addition to the effective use of sound insulating mate
rials, construction of a special noise abatement com
partment might be considered to reduce noise levels.
Such a compartment might be construe Led as follows
(Figure 6.7, page 25):
• Use 5/8-inch thick or 3/4-inch thick plywood in the
compartment.
•
Construct the compartment floor of a double thick
ness of 5/8-inch or 3/4-inch plywood.
• Line the compartment interior walls and floor, as well
as the underside of the floor, with 26-gauge galva
nized steel.
S'liJ Generac* Power Systems, Inc.