9 optional accessories, Optional accessories, 5 battery cable connections – Generac Power Systems 009600-4 User Manual
Page 36: 1 remote panel models, 4 battery compartment
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

INSTALLATION
Section 6 - Installation
PRlMEPACr 66G and 66LP Recreational Vehicle Generators
CABLE LENGTH
in Feet (meters)
CABLE SIZE
0 to 10 (0 to 3)
2* *
1 1 to 15 (3,4 to 4.5)
0
16 to 20 (4.5 to 6)
000
*For warm weather, use No. 2 cable up to 20 feet.
♦ 6.8.5 BATTERY CABLE CONNECTIONS
1.
Connect the battery cable from the battery post or
terminal indicated iay a POSITIVE, POS or ( + ) to the
lug on the starter contactor (Figure 6.20).
NOTE:
Check to be sure the battery cable boot for the
starter cable has been installed.
2.
Connect the battery cable from the battery post indi
cated by a NFfGATlVE. NEG or (-) to the frame
ground coimectioii (Figure 6.20).
Connect
cables
so
the
connectors
are
clean
and tight.
Figure 6.20 - Connecting Battery Cables
SIDE VIEW OF GENERATOR
3.
6.9
OPTIONAL ACCESSORIES
A plug-in receptacle (Figure 6.21) is provided on the
generator set, above tlie muffler enclosure. Use this
receptacle
to
connect
an
optional
remote-mounted
start/stop panel to the generator. Installation of such a
pane! will permit you to start and stop the generator
engine from any convenient location inside the vehicle.
Figure 6.21
-
Remote Panel Plug-in Receptacle
[#■
r
r;
WIRE #18-
(STOP)
WIRE #14
(ENGINE RUN
SIGNAL)
- WIRE #0
(GROUND)
WIRE #17
(CRA.NK)
• 6.9.1 REMOTE PANEL MODELS
The
remote
panels
mount
a
rocker
type
start/stop
switch, a "Generator Run” advisory lamp and an
hourmeter. The hourrneter should be used in conjunc
tion with the maintenance operations found in Part I of
this manual.
• Model 004057 includes the reinóte panel and a 10
fool long, 4 wire harness.
• Model 004184 includes the remote panel and a 30
foot long. 4 wire harness.
♦ 6.8.4 BATTERY COMPARTMENT
Install the generator battery in its own, vented compart
ment. Place the battery compartment away from any
source of heat, sparks or flame.
Provide ventilation openings in the battery compart
ment. The minimum size of openings should be 2
square inches at the top of the compartment. Mount the
battery on a strong, rigid supporting structure, where
leaks and spills of battery fluid will not cause damage.
34 Generac® Power Systems, Inc.