Section 2 - Operation
PRIMEPACT 66G and 66LP Recreational Vehicle Generators
OPERATION
♦ 2.4.5 ENGINE EXHAUST GAS____________________
Before starting the generator engine, you should be
sure there is no way for exhaust gases to enter the
vehicle
interior
and
endanger
people
or
animals.
Close windows, doors and other openings in the vehi
cle that, if open, might permit exhaust gases to enter
the vehicle.
DANGER
2.5
The generator engine gives off DEADLY carbon
monoxide gas through its exhaust system. This
dangerous gas, if breathed in sufficient concen
trations, can cause unconsciousness or even
death. Never operate the generator set with
the vehicle inside any garage or other enclosed
area. DO NOT OPERATE THE GENERATOR IF THE
EXHAUST SYSTEM IS LEAKING OR HAS BEEN
DAMAGED. SYMPTOMS OF CARBON MONOX
IDE POISONING ARE (a) inability to think coher
ently; (b) vomiting; (c) twitching muscles; (d)
throbbing temples; (e) dizziness; (f) headaches;
(g) weakness; and (h) sleepiness. IF YOU FEEL
ANY OF THESE SYMPTOMS, MOVE INTO FRESH
AIR IMMEDIATELY. IF SYMPTOMS PERSIST, GET
MEDICAL HELP.
STARTING THE GENERATOR
NOTE:
Read the vehicle manufacturer’s instructions. The
owner/operator should become familiar with the
vehicle
in
which
this
generator
is
installed.
Differences
exist
between
vehicles.
For
example,
some vehicles may use a transfer switch to isolate
dockside power from the generator, while other
vehicles
may
use
an
isolating
receptacle.
Some
vehicles may be equipped with a DC converter
which allows the generator to power certain DC
lighting and other DC loads.
To crank and start the generator engine, proceed as
follows:
1.
Turn OFF electrical loads using the means pro
vided in your vehicle (such as a main line circuit
breaker or transfer switch).
NOTE:
If starting from the generator control panel, turn
OFF loads by setting the generator’s main circuit
breaker to the OFF (or open) position. If starting
from a remote panel, turn OFF loads using the
means provided in the vehicle (such as a main cir
cuit
breaker).
Electrical
load
circuits
will
be
turned ON after the generator has started, stabi
lized and warmed up.
2
.
3.
If you have not started the engine in more than
two weeks, press the Fuel Pump Primer switch
and hold it for about 10 seconds. However, if the
engine is warm, skip Step 2.
To crank and start the engine, hold the starf/stop
switch at START. Release the switch when the
engine starts.
5.
--------
M.
CAUTION
¿k
--------------
If the engine does not start after it has been
^ cranking for 15 seconds, release the Start/Stop
switch and wait 1 minute before trying again.
Holding the switch for longer than 15 seconds
can damage the starter motor.
Let the engine run at no-load for a few minutes to
stabilize and warm up.
Turn
ON
electrical
loads
using
the
means
provided (such as a main circuit breaker or
transfer switch).
2.6
STOPPING THE GENERATOR
1.
Turn OFF all electrical loads using the means
provided (such as a main circuit breaker or
transfer switch).
2.
Let generator run at no-load for a few minutes, to
stabilize internal engine generator temperatures.
3.
Place the Start/Stop switch in its STOP position.
The engine will come to a complete stop.
2J APPLYING LOADS TO GENERATOR
When
applying
electrical
loads
to
the
generator,
observe these guidelines:
• Before applying electrical loads, let the generator
stabilize and warm up for a minute or two.
• DO NOT overload the generator.
• 2.7.1
LETTING
THE ENGINE STABILIZE
The generator supplies correct rated voltage only at
the proper governed speed. Some electrical appli
ances may be extremely sensitive to voltage. Incorrect
voltages can damage such appliances.
If electrical loads are applied at reduced operating
speeds, such loads imposed on the engine when suf
ficient power is not available may shorten engine life.
Never turn ON electrical loads until after the genera
tor engine has started and stabilized at no-load.