Maintenance, 2 chancing the engine oil and/or oil filter, Note – Generac Power Systems 009600-4 User Manual
Page 14: Maintaining the engine air cleaner, 1 cleaning the foam precleaner, Changing the engine oil and/or oil pdlter
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

(¿XSgiagM^ "' ' Z. '
MAINTENANCE
Section 3 - Maintenance
PRIMEPACT 66G and 66LP Recreational Vehicle Generators
3.2
CHANCING THE ENGINE OIL
AND/OR OIL FILTER
• Change the engine oil after the first 25 hours of
operation (after the 25-hour break-in period, see
Section 2.8.5, Page 10). Thereafter, change the
oil every 100 operating hours. Change the oil more
frequently
if
operating
consistently
under
heavy
load or at high ambient temperatures.
• Change the engine oil filter after the first 25 hours
of operation, and every 100 operating hours there
after.
To change the oil and/or oil filter, proceed as
follows:
1.
Run the engine until it is thoroughly warmed up
(at
least
five
minutes)
then
shut
OFF
the engine.
2.
With the engine still warm from running, remove
the oil drain plug (Figure 3.1). Drain the oil into
a suitable container.
3.
After the oil has drained, replace the oil drain
plug. (If only changing the oil, go to step 7.)
4.
With the oil drained, remove the old oil filter by
turning it counterclockwise (Figure 3.2 on page 12).
5.
Apply a light coating of clean engine oil to the gas
ket of the new filter.
6.
Screw the new filter on by hand until its gasket
lightly contacts the oil filter adapter. Then, tight
en the filter an additional 3/4 to one turn.
7.
Remove the dipstick and fill crankcase with the
proper type and amount of recommended oil (see
Section 1.6.2, Page 6). The engine crankcase can
hold about 1.4 liters. DO NOT FILL /\BOVE THE
‘TULL’ MARK.
8.
Install and tighten the dipstick before operating
the engine.
9. Start the engine and check for leaks.
NOTE:
Check the oil level and fill to the “FULL’ mark after
checking for leaks. The filter will retain some oil.
Figure 3.1
—
Oil Dipstick/Fill Tube and
Location of Oil Drain Plug
3.3
MAINTAINING THE ENGINE
AIR CLEANER
♦ 5.5.1
CLEANING THE FOAM PRECLEANER
Clean and re-oil the foam precleaner every three
months or every 25 hours of operation, whichever
occurs first. Service the foam precleaner more fre
quently if operating the generator in extremely dusty
or
dirty
conditions.
Use
the
following
procedure
(Figure 3.3):
1. Turn the knob counterclockwise to loosen.
2.
Remove the cover, foam precleaner and paper fil
ter.
3. Remove the foam precleaner from the cover.
4.
Wash the foam precleaner in liquid detergent and
water.
5.
Wrap the foam precleaner in a clean cloth and
gently squeeze it dry.
6.
Saturate the foam precleaner in clean engine oil.
Gently squeeze it in a clean cloth to remove
excess oil and to distribute oil (DO NOT T’WIST).
7.
Install the foam precleaner into the cover, fol
lowed by the paper filter. Tabs at edges of paper
1 a Generac* Power Systems, Inc.