beautypg.com

Cl c l, Hearth requirements, Wall thimble centerline from floor – Vermont Casting 820 User Manual

Page 6: Wall and ceiling clearances

background image

6

6

Vermont Castings Jefferson Direct Vent/Natural Vent Gas Heater

20002191

Parallel Installation:

Minimum Clearance and Flue Centerline,

Direct Vent and Natural Vent

C

L

C

L

B

D

C

A

Stove Clearances

A: 4” (102mm)
B: 4” (102mm)

Pipe Centerlines

C: 14

¹⁄₂

” (369mm)

D: 9” (229mm)

ST128a

Fig. 3 Parallel installation, minimum back and side clearances,
and flue centerlines.

Hearth Requirements

The Jefferson Heater must be installed on rigid flooring.
When the heater is installed directly on any combustible
surface other than wood flooring, a metal or wood panel
extending the full width and depth of the unit must be
used as the hearth. There are no other hearth require-
ments.

A

Wall Thimble Centerline from Floor

A

Effective Minimum
Wall Thimble

58

¹

/

” (1480mm)(CFM Majestic Pipe)

Centerline

54

¹⁄₄

” (1378mm) (Simpson DuraVent Pipe)

ST131a

Fig. 5 Minimum wall thimble centerline.

Direct Vent Only

Wall and Ceiling Clearances

* needed for installing DuraVent Minimum Vent Kit #2792 or
CFM/Majestic Minimum Vent Kit #7TFSDVSK.

A

C

D

B

A: Rear Wall

4” (102mm)

B: Min. Clearance

43

¹⁄₂

” (1105mm)*

C: Min. Alcove Height

72” (1830mm)*

D: Max. Alcove Depth

48” (1220mm)

Sidewall Clearance

4” (102mm)

ST101a

Fig. 6 Dimensions and clearances to ceiling or alcove.

Direct Vent Only

Corner Installation: Minimum Clearance and

Flue Centerline, Direct Vent & Natural Vent

Stove Clearance

A: 4” (102mm)

Pipe Centerline

B: 14

³⁄₄

” (375mm)

ST129b

Fig. 4 Corner installation, minimum corner clearances and flue
centerline.

A

A

B

B

This manual is related to the following products: