beautypg.com

Install the vent adapter pipe – Vermont Casting 820 User Manual

Page 15

background image

15

Vermont Castings Jefferson Direct Vent/Natural Vent Gas Heater

20002191

Side Wall Terminations: Dry fit the inner elbow

with the vertical inner vent and confirm the centerline
alignment with the wall thimble opening.

4. Attach the Inner Vent Assembly to the stove.

Run a bead of sealant around the bottom end of

the starter pipe and attach the assembly to the stove
using three 1/4-20 x 3/8” Phillips screws provided in
the parts bag. (Fig. 18)

5. Install the Outer Adapter Pipe. Apply a 1/4” bead

of cement around the inside wall of the pipe, about
1” from the end. Insert the pipe over the stove flue
collar, keeping the vertical seam oriented to the back
of the stove. Also, be sure to align holes on the pipe
with the holes on the flue collar of the firebox.
Fasten the pipe to the holes in the flue collar with the
#12 x 1/2” sheet metal screws provided. (Fig. 19)

CEM

EN

T

First Section of
Vent Pipe

1/4”-20 x 1/2”
Phillips Screw

3” Inner
Starter
Pipe

ST211

Fig. 17 Connect the inner starter with the next section of
inner vent pipe.

Fig. 18 Attach inner assembly to flue collar.

ST212

CEMENT

ST213

Fig. 19 Fasten outer pipe with #12 x 1/2” sheet metal screw.

Install the Vent Adapter Pipe

(Simpson Dura-Vent Components)

1. Install the Restrictor Plate. Consult the ‘Vent Run

Specifications’ on page 8 to determine whether the
restrictor plate is needed. If so, put the restrictor
plate in place within the inner flue collar as shown in
Figure 16.

2. Discard the inner starter pipe shipped with the

logset. Using the starter pipe assembly listed on
page 7, slide the inner section out to allow access.

Run a bead of sealant around the bottom end of

the starter pipe and attach the assembly to the stove
using three 1/4-20 x 3/8” Phillips screws provided in
the parts bag. (Fig. 20)

3. Install the Outer Adapter Pipe. Apply a 1/4” bead

of cement around the outside surface, about one
inch from the crimped end. (Fig. 21) Orient the
vertical seam to the rear, and insert the crimped end
of the outer pipe into the flue collar. Fasten with
three sheet metal screws provided.

ST355

Fig. 20 Simpson Dura-Vent - install inner adapter pipe.

CE

ME

NT

Inner Adapter
Pipe

1/4-20 x 3/
8 Phillips
Screws

This manual is related to the following products: