beautypg.com

General venting information - termination location – Vermont Casting 820 User Manual

Page 10

background image

10

10

Vermont Castings Jefferson Direct Vent/Natural Vent Gas Heater

20002191

V

V

V

V

V

V

V

X

X

X

D

E

B

B

B

C

B

M

B

A

J

K

F

L

VENT TERMINATION

AIR SUPPLY INLET

AREA WHERE TERMINAL IS NOT PERMITTED

H

I

Fixed

Closed

Fixed

Closed

Operable

Operable

Fixed

Closed

V

B

INSIDE

CORNER DETAIL

V

A

G

V

N

N

V

V

G

G

A

CFM145a

Fig. 9 Vent termination clearances.

A = Clearance above grade, veranda, porch,

12 inches (30cm)

12 inches (30cm)

deck, or balcony

B = Clearance to window or door that may be

6 in (15cm) for appliances

6 in (15cm) for appliances

opened

< 10,000Btuh (3kW), 12 in (30cm)

< 10,000 Btuh (3kW), 9 in

for appliances > 10,000 Btuh (3kW) and

(23cm) for appliances > 10,000

< 100,000 Btuh (30kW), 36 inches (91cm) Btuh (3kW) and < 50,000 Btuh
for appliances > 100,000 Btuh (30kW)

(15kW), 12 in (30cm) for
appliances > 50,000 Btuh (15kW)

C = Clearance to permanently closed window

12” (305mm) recommended to

12” (305mm) recommended to

prevent window condensation

prevent window condensation

D = Vertical clearance to ventilated soffit located

above the terminal within a horizontal

18” (458mm)

18” (458mm)

distance of 2 feet (610mm) from the center
line of the terminal

E = Clearance to unventilated soffit

12” (305mm)

12” (305mm)

F = Clearance to outside corner

see next page

see next page

G = Clearance to inside corner (see next page)

see next page

see next page

H = Clearance to each inside of center line

3 feet (91cm) within a height of 15 feet

3 ft (91cm) within a height of 15 ft

extended above meter/regulator assembly

above the meter/regulator assembly

above the meter/regulator assy

I = Clearance to service regulator vent outlet

3 feet (91cm)

3 feet (91cm)

J = Clearance to nonmechanical air supply inlet 6 inches (15cm) for appliances < 10,000

6 inches (15cm) for appliances

to building or the combustion air inlet to any Btuh (3kW), 12 inches (30cm) for

< 10,000 Btuh (3kW), 9 inches

other appliances

appliances > 10,000 Btuh (3kW) and <

(23cm) for appliances > 10,000

100,000 Btuh (30kW), 36 inches (91cm)

Btuh (3kW) and < 50,000 Btuh

for appliances > 100,000 Btuh (30kW)

(15kW), 12 inches (30cm) for
appliances > 50,000 Btuh (15kW)

K = Clearance to a mechanical air supply inlet

6 feet (1.83m)

3 feet (91cm) above if within 10
feet (3m) horizontally

L = Clearance above paved sidewalk or paved

7 feet (2.13m)†

7 feet (2.13m)†

driveway located on public property

M = Clearance under veranda, porch, deck or

12 inches (30cm)c

12 inches (30cm)†

balcony

N = Clearance above a roof shall extend a minimum of 24” (610mm) above the highest point when it passes through the roof

surface, and any other obstruction within a horizontal distance of 18” (450mm).

1 In accordance with the current CSA-B149 Installation Codes
2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes
† A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves
both dwellings
‡ only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor:
NOTE: 1. Local codes or regulations may require different clearances.

2. The special venting system used on Vermont Castings Direct Vent Stoves are certified as part of the appliance, with clearances
tested and approved by the listing agency.

Canadian Installations

1

US Installations

2

General Venting Information - Termination Location

This manual is related to the following products: