Vermont Castings Jefferson Direct Vent/Natural Vent Gas Heater

20002191

Venting Requirements - Natural Vent Only

Venting Runs

Horizontal Run (in feet)

Ve

rtical Run (in f

eet)

(Measured from floor of unit to

top of v

ent cap

.)

A: Vertical installations up to 36 feet (12m) in
height. Up to an 18 ft. horizontal vent run can be
installed within the vent system using a
maximum of two 90-degree elbows or four
45-degree elbows.

B: Vertical installations up to 36 feet (12m) in
height. Up to a 24 ft. horizontal vent run can be
installed within the vent system using a
maximum of two 45-degree elbows.
(Ratio = 2/3, Hor./Vert.)

= Acceptable venting configuration

= Unacceptable venting configuration

36

34

32

30

28

26

24

22

20

18

16

14

12

10

8

16 18 20 22 24 26 28 30 32 34 36

4 6 8 10 12 14

A

B

Fig. 11 Vent termination window - Natural Vent ONLY.

FP567b

NOTE: When using the FSDHAG, the restrictor plate
supplied with the stove is not used.

Outside Corner

Inside Corner

Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.

A =
Combustible
6"(152mm)

Noncombustible
2"(50mm)

B =
Combustible
6"(152mm)

Noncombustible
2"(50mm)

A

Balcony -
with no side wall

G =
Combustible&
Noncombustible
12"(305mm)

G

Balcony -
with perpendicular side wall

H = 24"(610mm)

J = 20"(508mm)

H

J

B

Recessed Location

C = Maximum depth of 48"
(1219mm) for recessed
location.

D = Minimum width for back wall
of a recessed location.
Combustible 38"(965mm)
Noncombustible 24"(610mm)

E = Clearance from corner in
recessed location.
Combustible 6"(152mm)
Noncombustible 2"(50mm)

C

D

C

E

V

V

Combustible &
Noncombustible

V

V

V

584-14

Fig. 10 Termination clearances.