39-7/8
11/16-
——28-1/2-
VENT CONN
13/16
7/8 DIA HOLE-
POWER ENTRY
7/8 DIA
ACCESSORY
1-3/4 DIA HOLE
GAS ENTRY
1/2 DIA HOLE
THERMOSTAT
WIRE ENTRY
SIDE INLET
5-è/8 I
H
12-5/16
5-13/16
24-5/16-
11/16
14-1/2
NOTE: 2 ADDITIONAL 7/8 DIA KNOCKOUTS
ARE LOCATED IN THE TOP PLATE
NOTE: AIR DELIVERY ABOVE 1800 CFM REQUIRES THAT BOTH SIDES OF FURNACE
BE USED, OR A COMBINATION OF 1 SIDE AND BOTTOM, OR BOTTOM ONLY FOR
RETURN AIR.
A88367
A88367
Fig. 1—Dimensional Drawing
National NFGC. Canadian installations must be installed in
accordance NSCNGPIC and all authorities having jurisdiction. For
further information, the National Fuel Gas Code is available from
National Fire Protection Association Inc. Batterymarch Park,
Quincy, MA 02269, American Gas Association, 1515 Wilson
Boulevard, Arlington, VA 22209, or from Literature Distribution.
Installation must conform to the regulations of the serving gas
supplier and the local building, heating, and plumbing codes in
effect in the area in which the installation is made, or in the
absence of local codes with the requirements of the NFGC.
A
CAUTION
Application of this furnace should be indoors with special
attention given to vent sizing and material, gas input rate, air
temperature rise, and unit sizing. Improper installation or
misapplication of the furnace can require excessive servicing
or cause premature component failure.
Table 2—Dimensions (In.)
UNIT SIZE
A
D
E
VENT CONN SHIP. WT
045-08
14-3/16 12-9/16 12-11/16
4
116
045-12
14-3/16 12-9/16 12-11/16
4
118
070-08
14-3/16 12-9/16 12-11/16
4
126
070-12
14-3/16 12-9/16 12-11/16
4
128
090-14
17-1/2
15-7/8
16
4
143
090-16
21
19-3/8
19-1/2
4
147
111-12
17-1/2
15-7/8
16
4
153
111-16
21
19-3/8
19-1/2
4
159
111-20
24-1/2
22-7/8
23
4
176
135-16
21
19-3/8
19-1/2
5
171
135-20
24-1/2
22-7/8
23
5
186
155-20
24-1/2
22-7/8
23
5
196
This furnace is designed for a minimum continuous return-air
temperature of 60°F db or an intermittent operation down to 55 °F
db such as when used with a night setback thermostat. Return-air
temperature must not exceed a maximum of 85°F db.
A
WARNING
Improper installation, adjustment, alteration, service, mainte
nance, or use can cause carbon monoxide poisoning, explo
sion, fire, electrical shock, or other conditions which may
cause personal injury or property damage. Consult a qualified
installer, service agency, local gas supplier, or your distribu
tor or branch for information or assistance. The qualified
installer or agency must use only factory-authorized and
listed kits or accessories when modifying this product. A
failure to follow this warning can cause electrical shock, fire,
personal injury, or death.
NOTE;
Remove all shipping brackets and materials before
operating the furnace.
Step 1—Location
GENERAL
A
CAUTION
Do not in'stall furnace in a corrosive or contaminated atmo
sphere. Make sure all combustion and circulating air require
ments are met, in addition to all local codes and ordinances.
For accessory installation details, refer to the applicable instruction
literature.