7. Open K-W circuit.
8. Disconnect slope gage.
9. Remove plastic tees and reconnect factory pressure
tubes to gas valve and pressure switch.
10. Turn on gas supply to furnace.
Ignition System Check—
When all connections have been
checked, light the furnace using procedure outlined on light
ing instruction attached to furnace. When lighting the fur
nace for the first time, however, perform the following addi
tional steps:
1. If gas supply was not piurged before connecting fur
nace, line will be full of air. Loosen ground joint union
and allow supply line to purge until gas odor is
detected. Never purge gas lines into a combustion
chamber. Immediately upon detection of gas odor,
retighten union. After 5 minutes, light fmrnace in
accordance with instructions on furnace rating plate.
2. Main burners should light 25 to 75 seconds after pilot.
If main burners do not light within prescribed time
period, check pilot ñame.
3. The pilot ñame should be soft blue in color and it must
provide good impingement on the pilot switching ele
ment. The ñame should extend above the burner carry
over port to provide a proper burner ignition. When the
pilot flame requires adjustment:
a. Locate adjustment screw marked “PILOT ADJ” on
top of gas valve.
b. Remove cap and turn adjustment screw clockwise
to decrease pilot gas flow. Turn screw counterclock
wise to increase pilot gas flow.
c. When proper adjustment is obtained, replace screw
cap.
Gas Input
NOTE:
Be sure reference pressmre tube, combustion-air and
vent pipes, and burner enclosure front are in place when
clocking the gas meter.
1. Determine gas input.
a. Turn off all other gas appliances and pilots.
b. Measure time (in seconds) for gas meter test dial to
complete one revolution.
c. Refer to Table 4 for cu ft of gas per hour.
d. Multiply cu ft/hr by heating value of gas (Btu/cu ft)
obtained from local gas utility.
EXAMPLE:
Btu heating input = Btu/cu ft times cu ft/hr
Heating value of gas = 1070 Btu/cu ft
Time for one revolution of 2-cu-ft dial = 72 sec
Gas rate = 100 cu ft/hr (from Table 4)
Btu heating input = 1070x100 = 107,000 Btuh
e. Measm-ed gas input must not exceed gas input on
unit rating plate.
2. To adjust input rate:
a. Remove burner enclosure front and cap that con
ceals adjustment screw for gas valve regulator.
b. Turn adjusting screw either counterclockwise (out)
to decrease input rate or clockwise to increase rate.
When adjusting input rate, do NOT change mani
fold pressure more than 3.2 minimum to 3.8 maxi
mum in. wc. Make any major adjustments by
changing main burner orifices.
NOTE:
Manifold pressure must always be measured with
burner enclosure front removed. The gas meter must always
be clocked with burner enclosure front installed.
DIGITAL MANOMETER
A84220
Fig. 6—Tuning Valve Adjustment
c.
Replace burner enclosure front and measure
adjusted gas input rate using method outlines in
step 1.
d. Replace cap that conceals gas valve regulator
adjustment screw.
A CAUTION
Be sure burner enclosure front is in place after adjust
ments have been made.
3. Look through sight glass in burner enclosure and check
burner and pilot flame. The main biurner flame should
be clear blue, almost transparent. The pilot flame
should be well defined. See Fig. 7.
Table 4—Gas Rate in Cu Ft/Hr
SECONDS
SIZE OF
SECONDS
SIZE OF
FOR ONE
TEST DIAL
FOR ONE
TEST DIAL
REVOLU-
1
2
5
REVOLU-
1
2
5
TION
cu ft
cu ft
cu ft
TION
cu ft
cu ft
cu ft
10
360
720
1800
50
72
144
360
11
327
655
1636
51
71
141
355
12
300
600
1500
52
69
138
346
13
277
555
1385
53
68
136
340
14
257
514
1286
54
67
133
333
15
240
480
1200
55
65
131
327
16
225
450
1125
56
64
129
321
17
212
424
1059
57
63
126
316
18
200
400
1000
58
62
124
310
19
189
379
947
59
61
122
305
20
180
360
900
60
60
120
300
21
171
343
857
62
58
116
290
22
164
327
818
64
56
112
281
23
157
313
783
66
54
109
273
24
150
300
750
68
53
106
265
25
144
288
720
70
51
103
257
26
138
277
692
72
50
100
250
27
133
267
667
74
48
97
243
28
129
257
643
76
47
95
237
29
124
248
621
78
46
92
231
30
120
240
600
80
45
90
225
31
116
232
581
82
44
88
220
32
113
225
563
84
43
86
214
33
109
218
545
86
42
84
209
34
106
212
529
88
41
82
205
35
103
206
514
90
40
80
200
36
100
200
500
92
39
78
196
37
97
195
486
94
38
76
192
38
95
189
474
96
38
75
188
39
92
185
462
98
37
74
184
40
90
180
450
100
36
72
180
41
88
176
439
102
35
71
178
42
86
172
429
104
35
69
173
43
84
167
419
106
34
68
170
44
82
164
409
108
33
67
167
45
80
160
400
110
33
65
164
46
78
157
391
112
32
64
161
47
76
153
383
116
31
62
155
48
75
150
375
120
30
60
150
49
73
147
367
—6—