Fig. 7—wiring diagram – Carrier 58EFA User Manual
Page 5
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
U\
L1(H)-
I
115 VAC 1 0 60 HZ POWER SUPPLY
(FUSED DISCONNECT ON HOT LEG) '
Li!(N)
---------- TRANSFORMER
AC
CONDENSING
UNIT ■
IGNITION MODULE
HONEYWELL S8600
OR S8660
MV
M\APV PV
24V
24V (GNO)
GNO (BURNER)
SPARK
NOTES: (1) MAKEFIELD POWER SUPPLY CONNECTIONS TO BLACK AND WHITE WIRES
CAPPED WITH ORANGE WIRE NUTS.
(2) WARNING ••• UNIT MUST BE GROUNDED. WIRING MUST CONFORM TO N.E.C. AND
LOCAL CODES.
(3) IF ANY OF THE ORIGINAL WIRE, AS SUPPUED WITH THE FURNACE. MUST BE
REPLACED. IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A
TEMPERATURE RATING OF AT LEAST 185 C AND BE A MINIMUM OF 16 GA.
AWC COPPER STRAND WIRE.
(4) CONNECT REQUIRED MOTOR LEAD TO HEAT TERMINAL ON CIRCUIT BOARD TO
DELIVER A TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING
PLATE. CONNECT UNUSED MOTOR LEADS TO THE ‘Ml 4 M2* TERMINALS.
Fig. 7—Wiring Diagram