beautypg.com

Tv operations, Md changer operations – Clarion XDZ716 User Manual

Page 11

background image

XDZ716

21

20

XDZ716

MD Changer Operations

TV tuner functions

When an optional TV tuner is connected through
the CeNET cable, this unit controls all TV tuner
functions. To watch TV requires a TV tuner and
monitor.

Watching a TV

1. Press FNC button

3

and select the TV mode.

2. Press BND button

"

to select the desired TV

band (TV1 or TV2). Each time the button is
pressed, the input selection toggles between
TV1 and TV2.

3. Press the right or left side of SEARCH button

%

to tune in the desired TV station.

Watching a video

The TV tuner has a VTR input terminal to which
1 external device can be connected. Connect a
12 V video cassette player (VCP) or video cas-
sette recorder (VCR) to the TV tuner input termi-
nal.

1. Press RDM button

7

to select VTR.

2. To return to the TV broadcast, press RDM

button

7

.

Tuning

There are 3 types of tuning mode available, Seek
tuning, manual tuning and preset tuning.

Seek tuning

1. Press BND button

"

and select the desired

TV band (TV1 or TV2).

If “MANU” is lit in the display, press and hold

BND button

"

for 1 second or longer. “MANU

in the display goes off and seek tuning is now
available.

2. Press the right or left side of SEARCH button

%

to automatically seek a station. Press the

right side of SEARCH button

%

to auto-

matically tune up the frequency band to the
next available TV station; press the left side
to automatically tune down.

Manual tuning

There are 2 ways available: Quick tuning and step
tuning.

When you are in the step tuning mode, the fre-
quency changes one step at a time. In quick tun-
ing mode, you can quickly tune the desired fre-
quency.

TV Operations

2. To cancel the disc scan play, press and hold

SCN button

5

again. “DISC” and “SCN” go

off from the display and the current track con-
tinues to play.

Repeat play

The repeat play continuously plays the current
track. This function continues automatically until
it is cancelled.

1. Press RPT button

6

. “RPT” lights in the dis-

play and the current track is repeated.

2. To cancel the repeat play, press RPT button

6

again. “RPT” goes off from the display and

normal play resumes.

Disc repeat play

After all the tracks on the current disc have been
played, the disc repeat play automatically replays
the current disc over from the first track. This func-
tion continues automatically until it is cancelled.

1. Press and hold RPT button

6

for 1 second

or longer. “DISC” and “RPT” light in the dis-
play and the disc repeat play starts.

2. To cancel the disc repeat play, press and hold

RPT button

6

again. “DISC” and “RPT” go

off from the display and normal play resumes
on the current track.

Random play

The random play selects and plays individual
tracks on the disc in no particular order. This
function continues automatically until it is can-
celled.

1. Press RDM button

7

. “RDM” lights in the dis-

play and the random play begins.

2. To cancel the random play, press RDM but-

ton

7

again. “RDM” goes off from the dis-

play and normal play resumes.

Disc random play

The disc random play selects and plays individual
tracks or discs automatically in no particular
order. This function continues automatically until
it is cancelled.

1. Press and hold RDM button

7

for 1 second

or longer. “DISC” and “RDM” light in the dis-
play and the disc random play starts.

2. To cancel the disc random play, press and hold

RDM button

7

again. “DISC” and “RDM” go

off from the display and normal play resumes
from the current track.

MD Changer Operations

MD changer functions

When an optional MD changer is connected
through the CeNET cable, this unit controls all
MD changer functions. This unit can control a
total of 2 changers (MD and/or CD).

Press FNC button

3

and select the MD changer

mode to star t play. If 2 MD changers are
connected, press FNC button

3

to select the

MD changer for play.

If “NO DISC” appears in the display, load MDs

into the MD changer.

Pausing play

1. Press Play/pause button

&

to pause play.

PAUSE” appears in the display.

2. To resume play, press Play/pause button

&

again.

Switching disc titles and track titles

This unit can display disc titles and track titles
already entered on MDs. Titles up to 128
characters long can be displayed by scrolling the
titles.

Titles cannot be entered for MDs with this unit.

1. Press DISP button

#

to display the title. The

disc title or track title is displayed.

2. Each time you press and hold DISP button

#

for 1 second or longer, the display toggles

between the disc title and the track title.

Procedure to scroll a title

Set “AUTO SCROLL” to “ON” or “OFF”. (The fac-
tory default setting is “ON”. See p.17.)

When set to “ON”

The title is automatically kept scrolling.

When set to “OFF”

Press the TITLE button

2

to scroll the title.

Selecting an MD

Each Direct button

9

corresponds to an MD

loaded into the MD changer. Press the corre-
sponding Direct button

9

(1 to 6) to select the

desired disc.

If an MD is not loaded in a slot of MD changer,

pressing Direct button

9

corresponding to its disc

number is invalid.

Selecting a track

Track-up

1. Press the right side of SEARCH button

%

to

move ahead to the beginning of the next track.

2. Each time you press the right side of SEARCH

button

%

, the track advances ahead to the

beginning of the next track.

Track-down

1. Press the left side of SEARCH button

%

to

move back to the beginning of the current track.

2. Press the left side of SEARCH button

%

twice

to move to the beginning of the previous track.

Fast-forward/fast-backward

Fast-forward

Press and hold the right side of SEARCH button

%

for 1 second or longer.

Fast-backward

Press and hold the left side of SEARCH button

%

for 1 second or longer.

Top function

The top function plays from the first track (track
No. 1) of the disc. Press Direct button

9

(1 to 6)

with the same number as the MD playing.

If an MD is not loaded in a slot of MD changer, press-

ing Direct button

9

corresponding to its disc num-

ber is invalid.

Scan play

The scan play locates and plays the first 10
seconds of each track on a disc automatically. This
function continues on the disc until it is cancelled.

The scan play is useful when you want to select a

desired track.

1. Press SCN button

5

to start track scanning.

SCN” lights in the display.

2. To cancel the scan play, press SCN button

5

again. “SCN” goes off from the display and
the current track continues to play.

Disc scan play

The disc scan play locates and plays the first 10
seconds of the first track on each disc in the
currently selected MD changer. This function
continues automatically until it is cancelled.

The disc scan play is useful when you want to

select a desired MD.

1. Press and hold SCN button

5

for 1 second

or longer. “DISC” and “SCN” light in the dis-
play and the disc scan play starts.