beautypg.com

Lp tank sizing, Lp/ng fuel conversion – Winco ULPSS15B2W/E User Manual

Page 8

background image

088-00

8

60706-207

Shown below is a diagram of a natural gas (NG)

installation.

Reference numbers 2 through 4 in the diagram

above are system parts supplied by the customer.

Reference number 4 is on the generator.

Below are tables of the fuel pressure readings at

each reference in the system.

FUEL PRESSURE TABLES

Single Low Pressure Regulator (LP Vapor only)

REF #

1

3

4

UNIT OFF

LINE PSI

7-11 IN

4-6 OZ

7-11 IN

4-6 OZ

STARTING

LINE PSI

7-11 IN

4-6 OZ

7-11 IN

4-6 OZ

NO LOAD

LINE PSI

7-11 IN

4-6 OZ

7-11 IN

4-6 OZ

FULL

LOAD

LINE PSI

7-11 IN

4-6 OZ

7-11 IN

4-6 OZ

Two (2) Regulator System (LP Vapor only)

REF #

1

2

3

4

UNIT

OFF

LINE PSI

10-15

LBS

7-11 IN

4-6 OZ

7-11 IN

4-6 OZ

START-

ING

LINE PSI

10-15

LBS

7-11 IN

4-6 OZ

7-11 IN

4-6 OZ

NO

LOAD

LINE PSI

10-15

LBS

7-11 IN

4-6 OZ

7-11 IN

4-6 OZ

FULL

LOAD

LINE PSI

10-15

LBS

7-11 IN

4-6 OZ

7-11 IN

4-6 OZ

Natural Gas

REF #

2

3

4

UNIT OFF

2 PSI

7-11 IN

4-6 OZ

7-11 IN

4-6 OZ

STARTING

2 PSI

7-11 IN

4-6 OZ

7-11 IN

4-6 OZ

NO LOAD

2 PSI

7-11 IN

4-6 OZ

7-11 IN

4-6 OZ

FULL

LOAD

2 PSI

7-11 IN

4-6 OZ

7-11 IN

4-6 OZ

LP TANK SIZING

Required LP tank size for LP Vapor withdrawal

operating at various outside temperatures given in

degrees Fahrenheit (Celsius).

TANK TEMPERATURE

TANK SIZE

60° F (16° C)

150 GALLON

32° F (0° C)

250 GALLON

0° F (18° C)

500 GALLON

-20° F (-29° C)

1000 GALLON

LP/NG FUEL CONVERSION

These generator sets are factory tested on Natural

Gas and will require no modifications for normal

operation on Natural Gas. The carburetion system

has been preset and anti-tamper plugs have been

installed in the carburetor as required by the EPA.

To make a fuel conversion you will have to first re-

move the cover panel on the left side of the genera-

tor set, directly above the fuel inlet. Locate the fuel

line to the engine, connected to the fuel outlet tee. It

should be connected to the NG port of the fuel outlet

tee. If you are going to operate on LP you will need

to move the fuel line from the NG port to the LP port

on the fuel outlet tee. These two ports have different

orifice inserts installed in them, which provide proper

operation with no further adjustments.

When moving the fuel line from one port to the other

be sure not to kink or bend the line. Use as large a

sweeping curve as possible and never shorten the

fuel line. For proper operation the fuel line must stay

the same length as it was shipped.