Front panel configuration 1 2 3 4 – Winco ULPSS15B2W/E User Manual
Page 19
9
088-00
60706-207
FRONT PANEL CONFIGURATION
1
2
3
4
This configuration mode allows the operator limited customizing of the way the module
operates. Use the module’s navigation buttons to traverse the menu and make value
changes to the parameters.
. ACCEPT button. 2. NEXT PAGE button.
3. DECREASE VALUE / NEXT ITEM 4. INCREASE VALUE / NEXT ITEM
ACCESSING THE FRONT PANEL
Press (accept) and 2 (next page)
simultaneously (at the same time). This display
shows the configuration icon: The first parameter is also displayed.
EDITING A PARAMETER
Enter the editor as described above.
* Press 2 to select the required ‘page’ as detailed below.
* Press 4 to select the next parameter or 3 to select the previous parameter within the
current page.
* When viewing the parameter to be changed, press the button. The value begins to
flash.
* Press 4 or 3 to adjust the value to the requested setting.
* Press to save the current value. The value stops flashing.
* Press and hold the button to exit the editor, the configuration icon is removed
from the display.
NOTE: Values representing pressure will be displayed in Bar. Values representing tem-
perature are displayed in degrees Celsius.
NOTE: When adjusting values in the front panel editor a press and hold of the increment
button will cover the full range of the item being adjusted (min to max) in under 20 sec-
onds.