“Concealed Damage” is understood to mean dam-

age to the contents of a package which is not

evident at the time of delivery by the carrier, but

which is discovered later. The carrier or carriers are

responsible for merchandise lost or damaged in tran-

sit. The title to goods rests with the consignee when

generators are shipped F.O.B. factory, and only the

consignee can legally file a claim. Please note, most

carriers have a time limit for filing concealed damage

claims.

**** CAUTION ****

These units are shipped with oil. Be sure to check

oil levels before operating. See engine manufactur-

er’s instruction manual for recommended oil require-

ments before initial starting.

UNPACKING

. Carefully remove the carton.

2. After inspecting the engine-generator and trans-

fer switch for external physical damage, check

for the following items packed inside the carton.

a. Owner’s manual.

b. Engine manufacturer’s instruction manual.

3. Remove main frame hold down bolts. (4)

4. Unit can now be lifted from shipping pallet.

INSTALLATION

General Information

******************

***** WARNING *****

******************

Before proceeding with the installation be sure the

operation selector switch is in the stop position.

These engine generator sets are designed to be

mounted on a concrete pad outdoors only. As an

option a prefab pad may be used as long as proper

attention is paid to site preparation to ensure the unit

will not move after installation. The transfer switch is

mounted next to your electrical entrance or distribu-

tion panel inside or outside the building. Consult a

qualified, licensed electrician or contractor to install

and wire the transfer switch.

The installation must

comply with all national, state and local codes.

Before beginning the installation process check the

rating of the generator set and its transfer switch

rating. Be certain they can handle the intended load

and are compatible with the entrance voltage, phase

and current ratings. Plans for installation should be

prepared with proper attention to mechanical and

electrical engineering detail to assure a satisfactory

system installation. The information in this manual is

offered only as a guide to finalizing your installation

plans.

SPECIFICATIONS

GENERATOR

MODEL WATTS*

VOLTS AMPS HZ PH RPM

PSS5

5000

20/240

62.5

60

3600

* Derate 6% for Natural Gas operation. Derate

3.5% per 000 feet elevation above sea level.

FUEL CONSUMPTION

NATURAL GAS

1000 BTU/CU FT

LP VAPOR

2520 BTU/CU FT

CF/HR

260

108

BTU/HR

260,000

272,160

GAL/HR

N/A

2.96

LBS/HR*

N/A

2.7

* Based on full load operation.

LP TANK SIZING

Required LP tank size for LP Vapor withdrawal

operating at various outside temperatures given in

degrees Fahrenheit (Celsius).

TANK TEMPERATURE

TANK SIZE

60° F (16° C)

150 GALLON

32° F (0° C)

250 GALLON

0° F (18° C)

500 GALLON

-20° F (-29° C)

1000 GALLON

ENGINE SPECIFICATIONS

Refer to engine operating and maintenance instruc-

tions.

** NOTICE **

When unpacking the generator set, be sure to in-

spect it carefully for freight loss or damage. If loss or

damage is noted at the time of delivery, require that

the person making the delivery make note of the loss

or damage on the freight bill, or affix his signature

under the consignor’s memo of the loss or damage.

Contact the carrier for claim procedures.

When loss or damage is noted after delivery, segre-

gate the damaged material, and contact the carrier

for claim procedures. Be sure to retain the packag-

ing material for carrier inspection.